2017 Page 1 of 4 SCOPE OF [PDF]

Vickers. (HV 300gf, 500gf). ASTM E384; ISO 6507-1. Impact (Charpy). ASTM A370, E23; ISO 148-1. Prevailing Torque. IFI 10

19 downloads 3 Views 387KB Size

Recommend Stories


2017 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO
There are only two mistakes one can make along the road to truth; not going all the way, and not starting.

2017 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO
Ego says, "Once everything falls into place, I'll feel peace." Spirit says "Find your peace, and then

2017 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO
If you feel beautiful, then you are. Even if you don't, you still are. Terri Guillemets

2017 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO
Ask yourself: Am I following the crowd or am I listening to my own heart and intuition? Next

2017 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO
Ask yourself: What do I allow to distract me from really living? Next

2017 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO
Ask yourself: Is there an area of your life where you feel out of control? Especially in control? N

2017 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO
In the end only three things matter: how much you loved, how gently you lived, and how gracefully you

Suite™ Page 1 of 4
Almost everything will work again if you unplug it for a few minutes, including you. Anne Lamott

2016 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO
I cannot do all the good that the world needs, but the world needs all the good that I can do. Jana

2017 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO 17025
You have to expect things of yourself before you can do them. Michael Jordan

Idea Transcript


SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

KPF 27327, 50, Chungjusandan 5-ro, Chungju-si, Chungcheongbuk-do, KOREA Kwang Yang Kim Youn O Choi Choong Il Lee Doyoon Kim

Email: [email protected] Email: [email protected] Email: [email protected] Email: [email protected] Phone: +82 43 849 1111 Fax: +82 43 849 1233

QM/Lab General Manger QM/Lab Manager QM & Technical Supervisor Hands-On Staff

MECHANICAL Valid To: October 31, 2020

Certificate Number: 0882.01

In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following fastener tests: Test Hardness Rockwell (HR30N, HRBW, HRC) Brinell (HBW) 10/3000kgf

Test Methods

ASTM A370, E18, F606/F606M; ISO 6508-1; SAE J417 ASTM A370, E10, F606/F606M; ISO 6506-1

Microhardness Vickers (HV 300gf, 500gf)

ASTM E384; ISO 6507-1

Impact (Charpy)

ASTM A370, E23; ISO 148-1

Prevailing Torque

IFI 101, 100/107; ISO 2320; DIN 267 Part 15 (1983)1

Proof Load Bolt (Length Measurement) Nut

(A2LA Cert. No. 0882.01) 11/15/2018

ASTM A370, F606/F606M; ISO 8981; SAE J429 ASTM A962/A962M, F606/F606M; ISO 898-2; SAE J995

Page 1 of 4

Test

Test Methods

Rotational Capacity

AS/NZS 1252; ASTM A325 (2014)1, A325M (2014)1, F3125/F3125M; EN14399-3, -4

Salt Spray

ASTM B117

Tensile Strength (Axial, Wedge, Full Size or Machined Specimens of Bolt/Stud)

ASTM A370, E8/E8M, F606/F606M; ISO 898-1, 6892-1; SAE J429

Yield Strength

ASTM A370, E8/E8M, F606/F606M; ISO 898-1, 6892-1

Elongation

ASTM A370, E8/E8M, F606/F606M; ISO 898-1, 6892-1

Reduction of Area

ASTM A370, E8/E8M, F606/F606M; ISO 898-1, 6892-1

Tension Control (Twist-off Bolts)

ASTM F1852 (2014)1, F2280 (2014)1, F3125/F3125M; EN 14399-10; JSS II09

Decarburization (Hardness Method & Optical Method)

ASTM E384, F2328; ISO 898-1; SAE J121 (2013)1, J429

Discontinuities

ASTM F788, F812; ISO 6157-1, -3; SAE J122, J123 (2012)1, J1061 (2012)1

Coating Thickness - Magnetic

ASTM B499

Non-Metal Layer on Iron Plating Thickness - X-ray (Fe/Zn)

Metallographic Evaluation Macroetch

ASTM B568, F1941/F1941M; ISO 4042

ASTM E381

Chemical Testing Chemical Composition Optical Emission Spectrometric on Carbon and Low Alloy Steel (Al, B, C, Co, Cr, Cu, Mn, Mo, Ni, P, S, Si, Ti, V) Optical Emission Spectrometric on Austenitic Stainless Steel (Al, B, C, Co, Cr, Cu, Mn, Mo, Ni, P, S, Si, Ti, V)

(A2LA Cert. No. 0882.01) 11/15/2018

ASTM E415 ASTM E1086

Page 2 of 4

I.

Dimensional Testing2:

Parameter

Range

CMC3 (±)

Technique / Method

Thread: Internal Thread

M10 to M64 3/8 to 3

N/A

Go/No Go plug gages / ASME B1.2; ISO 1502

External Thread

M10 to 64 3/8 to 3

N/A

Go/No Go ring gages / ASME B1.2; ISO 1502

Angle

Up to 360

0 038’

Profile projector / KS B 0239

Radius

Up to 60 R Up to 2.40 in

0.12 mm 0.0046 in

Profile projector / KS B 0239

Straightness

Bolt / Stud / Bar / Pin with Length up to 600 mm

N/A

Straightness gage / ASME B18.2.1

Slotted Width

Up to 75 mm Up to 3 in

N/A

Slot gages / ASME B18.2.2

Linear (1D)

Up to 600 mm Up to 24 in

0.09 mm 0.004 in

Calipers / KS B 0239

Up to 200 mm Up to 8 in

0.060 mm 0.0025 in

Digital calipers / KS B 0239

Up to 100 mm Up to 4 in

0.02 mm 0.001 in

Micrometer / KS B 0239

Up to 100 mm Up to 4 in

0.017 mm 0.0007 in

Digital micrometer / KS B 0239

Up to 50 mm Up to 2 in

0.018 mm 0.0007 in

Digital dial gage / JIS B1071

(A2LA Cert. No. 0882.01) 11/15/2018

Page 3 of 4

Parameter

Range

CMC3 (±)

Technique / Method

Linear (1D) (cont.)

Up to 0.80 mm Up to 0.030 in

0.018 mm 0.0007 in

Length Indicator / ASME B18.2.1

Linear (2D)

X axis: Up to 200 mm Up to 7.6 in Y axis: Up to 100 mm Up to 3.9 in

X axis: 7 m

Profile projector / KS B 0239

Surface Roughness

Ra Up to 3.8 m

1.1 m

Profilometer / ASME B46.1

Concentricity, Symmetry, and Run-Out

Up to 20.00 mm Up to 0.790 in

0.022 mm 0.0008 in

Concentricity gage with (threeroll gage) dial gage / JIS B1071

Y axis: 4 m

1

NOTE: This laboratory’s scope contains withdrawn or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now considered “historical” and not that the laboratory’s accreditation for the method has been withdrawn.

2

Commercial dimensional testing services are available for this laboratory. These tests are not equivalent to that of a calibration.

3

Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine measurements of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific measurement performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific measurement.

(A2LA Cert. No. 0882.01) 11/15/2018

Page 4 of 4

Accredited Laboratory A2LA has accredited

KPF

Chungju-si, Chungcheongbuk-do, KOREA, for technical competence in the field of

Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).

Presented this 15th day of November 2018.

_______________________ President and CEO For the Accreditation Council Certificate Number 0882.01 Valid to October 31, 2020

For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.

Smile Life

When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile

Get in touch

© Copyright 2015 - 2024 PDFFOX.COM - All rights reserved.