Abacus 5 Abacus 5 [PDF]

Stat & Rack mode, specific control material. (external reference – op onal). Quality Control. Separate QC database

3 downloads 5 Views 525KB Size

Recommend Stories


abacus
Happiness doesn't result from what we get, but from what we give. Ben Carson

abacus™ ii abacus™ ii
The beauty of a living thing is not the atoms that go into it, but the way those atoms are put together.

Avnet Abacus
The best time to plant a tree was 20 years ago. The second best time is now. Chinese Proverb

Running Abacus
If you want to become full, let yourself be empty. Lao Tzu

Abacus 380
Where there is ruin, there is hope for a treasure. Rumi

ABACUS Zeiterfassung
Everything in the universe is within you. Ask all from yourself. Rumi

Japanese Abacus Tutorial.pdf
Love only grows by sharing. You can only have more for yourself by giving it away to others. Brian

Abacus and Roman Numerals
Love only grows by sharing. You can only have more for yourself by giving it away to others. Brian

The Soroban – Japanese Abacus
You often feel tired, not because you've done too much, but because you've done too little of what sparks

Systemvoraussetzungen ABACUS Version 2017
We must be willing to let go of the life we have planned, so as to have the life that is waiting for

Idea Transcript


Parameters

Technology

Throughput Sample volume Sampling method Calibraon Quality Control Mul user mode User interface User languages Soware upgrade Data storage capacity Printout External keyboard Interfacing capabilies Size (W x H x D) Weight Operang environment

Autoloader Sample capacity Acceptable primary tubes Other features

Reagents** Diatro Dil-Diff (D50) Diatro Lyse-5P Diatro Diff-5P Diatro Hypoclean CC Your distributor:

Abacus 5 CBC+5 DIFF mode (24 parameters) - 2 histograms: RBC, PLT; 2 scaergrams: 4 diff, BASO WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC, PLT, PCT, MPV, PDW (sd/cv) Laser light scaer technology for 5-part WBC differenal Impedance method for CBC: WBC (80 μm), RBC and PLT (70 μm) Light absorbance for HGB measurement Cyanide-free reagent system Up to 60 tests/hour 100 μl (open/closed, whole blood) Closed and open tube sampling, auto-sampler (oponal) Stat & Rack mode, specific control material (external reference – oponal) Separate QC database, Levey-Jennings Charts Mullevel user modes with individual idenficaon (username, password) 600x800 color graphics LCD, touch screen (10.4”) Mullingual user interface Via USB port (USB memory sck) 100.000 records External, Microso® WindowsTM compable printers PS/2 or USB RS232, USB (4 pcs), Ethernet 40 x 50 x 45 cm 35 kg, with auto-sampler 45 kg Temperature: 15–35 °C Relave humidity: max 80% (non-condensing)

100 tubes: 10 racks with 10 sample tubes each Monovee®, Vacutainer®, Vacuee® Built-in bar code reader Built-in sample mixer Cap recognion (only tubes with caps are mixed and processed) Diluent Lysing reagent for quantave and qualitave determinaon of WBC, and HGB concentraon Lysing reagent for quantave determinaon of WBC, leukocyte five-part differenaon (LYM, MON, NEU, EOS, BAS) and hemoglobin (HGB) concentraon External cleaner for removing blood component precipitates from capillaries, tubings and chambers * Diatron reserves the right to change any of the specificaons without prior noce. ** Usage of original Diatron reagents is recommended Full specificaons are available on request or can be obtained from www.diatron.com (select ”products”.)

Diatron MI PLC Papírgyár u. 58-59. H-1038 Budapest, HUNGARY Phone: (36-1) 436 9800, fax: (36-1) 436 9809 www.diatron.com E-mail: [email protected]

Innovave Soluons in Hematology

Abacus 5

Abacus 5

Abacus 5

Abacus

Ease of use

5

is one of the high-end models of Diatron’s range of Hematology Analyzers. Its patented laser-based opcal measurement technology was developed by Diatron. It guarantees precise and accurate 5 part differenal results for human samples, and provides maximum value at low running costs.

High performance

• The instrument features an easy-to-use, logically constructed mullingual operang menu • Embedded soware enables easy connecon to a computer • Windows® compable printers are supported • Closed and open tube sampling method • Autoloader can be added at any me • Integrated bar code reader for rapid data processing

• Complete 24 parameter CBC profile including the opcal determinaon of the 5 part WBC differenal count • 60 samples per hour throughput (both in Stat & Rack mode) • Large color touch-screen, allowing fast and efficient work. Results are analyzed on 2 histograms and 2 scaergrams • More than 100.000 results database capacity • 4 USB ports

Reliable and efficient • The long lifeme laser diode ensures opmal performance using a high-tech flow cuvee • Abacus 5 requires minimal maintenance and so minimizes operaonal disrupon • Its compact size makes it suitable for laboratories with low desktop space • Diagnosc flagging system • Uses only 3 reagents • Walk-away system • Autoloader with a capacity of 100 vials • Cap recognion mechanism to avoid sampling errors