Development length of FRP - Fortec Stabilization Systems [PDF]

Development length of a FRP system is dependent on the bond capacity between the. FRP and substrate. To develop the bond

0 downloads 7 Views 37KB Size

Recommend Stories


strengthening of bridge slabs with frp systems
You can never cross the ocean unless you have the courage to lose sight of the shore. Andrè Gide

Development Length of 0.6-Inch (15-mm)
No amount of guilt can solve the past, and no amount of anxiety can change the future. Anonymous

the development of vowel length in slavic
Never wish them pain. That's not who you are. If they caused you pain, they must have pain inside. Wish

Active stabilization in robotic vision systems
In the end only three things matter: how much you loved, how gently you lived, and how gracefully you

lipooxygenase systems in development of
The butterfly counts not months but moments, and has time enough. Rabindranath Tagore

Development of National Statistical Systems
I cannot do all the good that the world needs, but the world needs all the good that I can do. Jana

Stabilization Proliferative Potential and Telomere Length Increased Antiviral Functions Accompany
In every community, there is work to be done. In every nation, there are wounds to heal. In every heart,

Stabilization
Love only grows by sharing. You can only have more for yourself by giving it away to others. Brian

FRP TANKS
If you want to go quickly, go alone. If you want to go far, go together. African proverb

FRP CUFFS
Pretending to not be afraid is as good as actually not being afraid. David Letterman

Idea Transcript


Development length of FRP    

Development length of a FRP system is dependent on the bond capacity between the FRP and substrate. To develop the bond-dependent, required FRP stress needed for strengthening a member the development length is governed by ACI 440.2R-08, equation 13-2: Ldf = 0.057*sqrt(n*Ef*tf/sqrt (f’c)) where: Ldf = Development length n = the number of FRP layers Ef = the tensile modulus of elasticity of the FRP tf = the thickness of one FRP layer f’c = the compressive strength of concrete If additional stresses on the FRP are required, or where substrate (concrete or masonry) crushing is the desired failure mode, mechanical anchorages are recommended. FRP fan-type anchors, perpendicular FRP bonded wraps, and grooveand-dowel anchors are a few types of suitable anchors. In addition, Fortress has developed a unique mechanical anchorage using a special version of its carbon staple and has been recently specified as the FRP anchor for a blast-resistant reinforcement upgrade at a petro-chemical facility in Ohio. If you are interested, the design of externally applied FRP systems, including development length is available as a spread sheet-based application at www.FRPcalc.com.  

Smile Life

When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile

Get in touch

© Copyright 2015 - 2024 PDFFOX.COM - All rights reserved.