2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 1/2. 1. Electronic timers. Table of contents

0 downloads 2 Views 2MB Size

Recommend Stories


BCH ELECTRONIC TIMERS & COUNTERS.pdf
How wonderful it is that nobody need wait a single moment before starting to improve the world. Anne

In The Picture Adam Walker
Before you speak, let your words pass through three gates: Is it true? Is it necessary? Is it kind?

Timers
Make yourself a priority once in a while. It's not selfish. It's necessary. Anonymous

Hart Walker Broşür (pdf)
Be who you needed when you were younger. Anonymous

754th Electronic Systems Group
Just as there is no loss of basic energy in the universe, so no thought or action is without its effects,

Untitled - Electronic Systems Group
Never wish them pain. That's not who you are. If they caused you pain, they must have pain inside. Wish

product data INDUSTRIAL
You often feel tired, not because you've done too much, but because you've done too little of what sparks

EUROPEAN MATERIALS HANDLING FEDERATION Product Group Industrial Trucks
Don't watch the clock, do what it does. Keep Going. Sam Levenson

asset - Go Walker [PDF]
Asset is an asset pipeline for revel (maybe possibly in the future) Assets have the extension .asset, for instance a javascript file would have the extension application.js.asset.

EUROPEAN MATERIALS HANDLING FEDERATION Product Group Industrial Trucks
If you want to go quickly, go alone. If you want to go far, go together. African proverb

Idea Transcript


Electronic timers Product group picture 1

1/1 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Electronic timers Table of contents Electronic timers Table of contents

1/2

Overview

1/3

Approvals and marks

1/4

CT-D range

1/5

Table of contents

1/6

Benefits and advantages

1/7

Ordering details

1/8

Function diagrams

1/9

Connection diagrams

1/12

Technical data

1/13

Technical data, Technical diagrams

1/15

Wiring notes, Dimensional drawings

1/16

CT-E range

1/17

Table of contents

1/18

Benefits and advantages

1/19

Ordering details

1/20

Function diagrams

1/22

Connection diagrams

1/27

Connection diagrams, Technical diagrams

1/28

Technical data

1/29

Wiring notes, Dimensional drawings

1/31

CT-S range

1/33

Table of contents

1/34

Benefits and advantages

1/35

Ordering details - multifunctional

1/37

Ordering details - singlefunctional

1/38

Ordering details - Accessories

1/39

Function diagrams

1/41

Connection diagrams

1/49

Technical data

1/52

Technical diagrams

1/55

Wiring notes, Dimensional drawings

1/56

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

1/2

1

Electronic timers Overview 1

CT-D range

CT-E range

CT-S range

Timing function

multifunctional

single-functional

multifunctional

single-functional

multifunctional

single-functional

A ON-delay

CT-MFD

CT-ERD

CT-MFE, CT-MKE

CT-ERE, CT-EKE

CT-MVS, CT-MFS, CT-MBS, CT-WBS

CT-ERS

B OFF-delay

CT-MFD

CT-AHD

CT-MFE

CT-AHE, CT-ARE, CT-AKE

CT-MVS, CT-MFS, CT-MBS

CT-APS, CT-AHS, CT-ARS, CT-VBS

AB

CT-MVS, CT-MXS, CT-MFS, CT-MBS

ON- and OFF-delay

CA Impulse-ON

CT-MFD

CB Impulse-OFF

CT-MFD

Impulse-ON and OFF

DA

Flasher starting with ON

CT-MFD

DB

Flasher staring with OFF

CT-MFD

DE or OFF

Flasher starting with ON

CT-VWE

CT-MVS, CT-MFS, CT-MBS, CT-WBS

CT-AWE

CT-MVS, CT-MFS, CT-MBS

CT-EBD

CT-MFE, CT-MKE CT-MFE, CT-MKE

CT-MFS, CT-MBS, CT-WBS CT-EBE

CT-TGD CT-MFD

CT-MXS CT-MFE

CT-MVS, CT-MFS, CT-MBS

CT-SDD, CT-SAD

CT-SDS

F

Star-delta change-over

FC

Star-delta change-over

CT-SDE

Star-delta change-over twice ON-delayed

CT-YDE

with impulse

FA

A+

AC

BC

further functions (depending on device)

G

Switching relay

CT-MVS.2x, CT-MFS, CT-MBS

CT-MVS, CT-MXS, CT-MFS, CT-MBS, CT-WBS

G



CT-MFS, CT-MBS, CT-WBS CT-MVS

ED Pulse generator starting with ON or OFF Pulse former

CT-MFE, CT-MKE

CT-MXS

CE

H

CT-VWD

CT-IRE

CT-IRS

Technical data (extract) Time ranges

7 (0.05 s - 100 h) CT-SDD, CT-SAD: 4 (0.05 s - 10 min)

Multifunction devices: 8 (0.05 s - 100 h) Single-function devices: 5 single ranges (0.05-1 s, 0.1-10 s, 0.3-30 s, 3-300 s, 0.3-300 min)

10 (0.05 s - 300 h) CT-ARS, CT-SDS: 7 (0.05 s- 10 min)

Control supply voltage

Wide and multi ranges

Wide ranges

Wide, multi and single ranges

Type and number of contacts

1 or 2 c/o contacts CT-SDD, CT-SAD: 2 n/o contacts

1 c/ o contact CT-SDE: 1 n/o contact and 1 n/c contact CT-MKE, CT-EKE, CT-AKE: 1 thyristor

1 or 2 c/o contacts CT-MVS.21, CT-MFS, CT-MBS: 2nd c/o contact selectable as inst. contact CT-SDS: 2 n/o contacts

Control inputs

voltage-related triggering, polarized, capable of switching a parallel load

voltage-related triggering, polarized CT-MFE, CT-AHE, CT-AWE: with auxiliary voltage

voltage-related triggering, non-polarized, capable of switching a parallel load CT-MFS, CT-MBS, CT-AHS: volt-free triggering

1/3 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Single and dual ranges

Electronic timers Approvals and marks CT-D CT-MFD.21

CT-ERD.12

CT-ERD.22

CT-AHD.12

CT-AHD.22

CT-VWD.12

CT-EBD.12

CT-TGD.12

CT-TGD.22

CT-SDD.22

CT-SAD.22

1

CT-MFD.12

J existing j pending

A

UL 508, CAN/CSA C22.2 No.14

J

J

J

J

J

J

J

J

J

J

J

J

K

CB scheme

J

J

J

J

J

J

J

J

J

J

J

J

EAC

j

j

j

j

j

j

j

j

j

j

j

j

J

J

Approvals

CCC

J

J

J

J

J

J

J

J

J

J

RMRS

J

J

J

J

J

J

J

J

J

J

a

CE

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

j

J

j

J

j

J

J

J

j

j

j

E

L Marks

CT-E CT-MFE

CT-ERE

CT-AHE

CT-ARE

CT-VWE

CT-AWE

CT-EBE

CT-YDE

CT-SDE

CT-IRE

CT-MKE

CT-EKE

CT-AKE

J existing j pending

A

UL 508, CAN/CSA C22.2 No.14

J

J

J

J

J

J

J

J

J

J

J

J

J

C

GL

J

J

J

J

J

J

J

J

J

J

J

J

J

K

CB scheme

J

J

J

J

J

J

J

J

J

J j

j

j

Approvals

EAC

j

j

j

j

j

j

j

j

j

j

E

CCC

J

J

J

J

J

J

J

J

J

J

L

RMRS

J

J

J

J

J

J

J

J

J

J

J

J

J

a

CE

J

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

J

J

J

J

J

J

J

J

J

J

J

J

Marks

CT-S CT-ERS.12S/P

CT-ERS.2xS/P

CT-APS.12S/P

CT-APS.2xS/P

CT-AHS.22S/P

CT-ARS.11S/P

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

j

j

EAC

j

j

j

j

j

j

j

j

j

j

j

j

K

CB scheme

J

J

J

J

J

J

J

J

J

J

J

E

CCC

J

J

J

J

J

J

J

J

J

J

L

RMRS

J

J

J

J

J

J

J

J

J

J

J

J

J

Rail applications 1)

J

CT-IRS.3x

CT-WBS.22S/P

J

J

CT-IRS.2x

CT-MBS.22S/P

J

J

CT-IRS.1x

CT-MFS.21S/P

J

GL

CT-SDS.2xS/P

CT-MXS.22S/P

UL 508, CAN/CSA C22.2 No.14

C

CT-VBS.1x

CT-MVS.2xS/P

A

Approvals

CT-ARS.21S/P

CT-MVS.12S/P

J existing j pending

J

J

J

j

j

j

j

j

j

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

Marks

1)

a

CE

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

b

C-Tick

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

Applicable in rail application following the latest standards for rail applications. Further information are available in our rail segment brochure 2CDC110084B0201.

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

1/4

CT-D range Product group picture 1

1/5 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

CT-D range Table of contents CT-D Range Product group picture

1/5

Table of contents

1/6

Benefits and advantages

1/7

Ordering details

1/8

Function diagrams

1/9

Connection diagrams

1/12

Technical data

1/13

Technical data, Technical diagrams

1/15

Wiring notes, Dimensional drawings

1/16

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

1/6

1

CT-D range Benefits and advantages Characteristics

Benefits

 Diversity: 2 multifunction timers 10 single-function timers  Control supply voltages: Wide range: 12-240 V AC/DC Multi range: 24-48 V DC, 24-240 V AC  7 time ranges from 0.05 s to 100 h or 4 time ranges from 0.05 s to 10 min  Width of only 17.5 mm  Light-grey housing in RAL 7035  Devices with: 1 c/o contact (250 V / 6 A) or 2 c/o contacts (250 V / 5 A) Control input: voltage-related triggering, polarized, capable of switching parallel loads  Approvals / Marks (partly pending, details see page 1/4)

A, K, E,

Direct reading scales

1

Direct setting of the time delay without any additional calculation provides accurate time delay adjustment. LEDs for status indication

2

All actual operational states are displayed by front-face LEDs, thus simplifying commissioning and troubleshooting. Switching currents The CT-D range timers allow an output load of up to 6 A on devices with 1 c/o contact and up to 5 A on devices with 2 c/o contacts. Connection terminals

3

Wide terminal spacing allows connection of wires: 2 x 1.5 mm² (2 x 16 AWG) with wire end ferrules or 2 x 2.5 mm² (2 x 14 AWG) without ferrules.

, L / a, b

Width 17,5 mm

4

With their width of 17.5 mm only, the CT-D range timers are ideally suited for installation in distribution panels.

Operating controls 1 LEDs for status indication U - green LED: V control supply voltage applied W timing R, R1, R2 - yellow LED: V output relay energized 2 Time range adjustment 3 Fine adjustment of the time delay 4 Preselection of the timing function

3 2

1 3

4 2

multifunctional

2CDC 253 021 F0004

3

2CDC 253 033 F0004

2

2CDC 253 132 F0006

1

single-functional

2CDC 253 066 F0006

1

4

17.5 mm

1/7 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

CT-D range Ordering details Description The CT-D range in MDRC design with a width of only 17.5 mm fits into all domestic installation and distribution panels. The CT-D range represents a link between industry and the installation types. For maximum flexibility in operation, 10 single-function as well as 2 multifunction devices with 7 timing functions are available. The devices offer 4 or 7 time ranges from 0.05 seconds up to 100 hours. Their wide input range allows the use in applications worldwide.. Ordering details

2CDC 251 089 F0006

Timing function

Rated control supply voltage

Time ranges

2CDC 251 091 F0006

Pulse former

ED F

Pulse generator Star-delta change-over

Price

Weight (1 pce)

1 pce

kg (lb)

CT-MFD.12

1SVR500020R0000

0.060 (0.132)

Multifunc- 12-240  V AC/DC tional1)

n

2 c/o

CT-MFD.21

1SVR500020R1100

0.065 (0.143)

-

1 c/o

CT-ERD.12

1SVR500100R0000

0.060 (0.132)

-

1 c/o

CT-ERD.22

1SVR500100R0100

0.065 (0.143)

n

1 c/o

CT-AHD.12

1SVR500110R0000

0.060 (0.132)

n

2 c/o

CT-AHD.22

1SVR500110R0100

0.065 (0.143)

CT-VWD.12

1SVR500130R0000

7 (0.05 s 100 h)

ON-delay

Flasher starting with ON

H

Order code

1 c/o

ImpulseON

ON-delay OFF-delay Impulse-ON Impulse-OFF Flasher starting with ON Flasher staring with OFF

Type

n

OFFdelay

A B CA CB DA DB

Output

Multifunc- 24-240 V AC 7 (0.05 s tional1) 24-48 V DC 100 h)

CT-MFD.12

CT-ERD.22

Control input

7 (0.05 s 100 h)

-

24-240 V AC 24-48 V DC

-

Pulse generator

2×7 (0.05 s 100 h)

Star-delta changeover

4 (0.05 s 10 min)

1 c/o

n n -

2 c/o 2 c/o

0.060 (0.132)

CT-EBD.12

1SVR500150R0000

CT-TGD.122)

1SVR500160R0000

0.060 (0.132)

CT-TGD.222)

1SVR500160R0100

0.065 (0.143)

CT-SDD.223)

1SVR500211R0100

CT-SAD.22

1SVR500210R0100

4)

0.065 (0.143)

1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former 2) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h n Control input with voltage-related triggering 3) Transition time 50 ms fixed - no triggering 4) Transition time adjustable

Synonyms used expression

alternative expression(s)

used expression

alternative expression(s)

1 c/o contact

SPDT

voltage-related

wet / non-floating

2 c/o contacts

DPDT

volt-free

dry / floating

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

1/8

1

CT-D range Function diagrams Remarks Legend

Terminal designations on the device and in the diagrams

G Control supply voltage not applied / Output contact open B Control supply voltage applied / Output contact closed A1-Y1/B1 Control input with voltage-related triggering

The 1st c/o contact is always designated 15-16/18. The 2nd c/o contact is designated 25-26/28. The n/o contacts of the star-delta timers are designated with 17-18 and 17-28. Control supply voltage is always applied to terminals A1-A2. Function of the yellow LED The yellow LED R glows as soon as the output relay energizes and turns off when the output relay de-energizes.

green LED t