Hiden CATLAB - Hiden Analytical [PDF]

and anaerobic conditions. ACS Catal., 2014, 4, pp 1032–1039 Giulia Tuci, Giuliano Giambastiani, Stephanie Kwon,. Peter

13 downloads 11 Views 1MB Size

Recommend Stories


Hiden QGA
Learning never exhausts the mind. Leonardo da Vinci

Hiden TPD Workstation
Almost everything will work again if you unplug it for a few minutes, including you. Anne Lamott

baish hiden ng publ lishin ng gro oup inc c
If you want to go quickly, go alone. If you want to go far, go together. African proverb

PDF Analytical Mechanics
So many books, so little time. Frank Zappa

[PDF] Analytical Mechanics Full Online
Forget safety. Live where you fear to live. Destroy your reputation. Be notorious. Rumi

PDF Analytical Methods for Lawyers
The beauty of a living thing is not the atoms that go into it, but the way those atoms are put together.

[PDF] Analytical Chemistry An Introduction
We may have all come on different ships, but we're in the same boat now. M.L.King

[PDF] Fundamentals of Analytical Chemistry
Nothing in nature is unbeautiful. Alfred, Lord Tennyson

PdF Analytical Profiles of Drug Substances
Those who bring sunshine to the lives of others cannot keep it from themselves. J. M. Barrie

Rosemount Analytical 5081FG Oxygen Analyzer Manual PDF
In the end only three things matter: how much you loved, how gently you lived, and how gracefully you

Idea Transcript


Hiden CATLAB Integrated Microreactor-Mass Spectrometer for Reaction Testing, TPD/R/O and Pulse Chemisorption

www.HidenAnalytical.com

Quadrupole Mass Spectrometers for Advanced Science

CATLAB Modules

QGA Gas Analyser

Microreactor

Temperature and Gas Control Unit

www.HidenAnalytical.com

Quadrupole Mass Spectrometers for Advanced Science

Standard CATLAB Layout

Module 2 Mass Spectrometer

Module 1 Microreactor and TCU/GCU

www.HidenAnalytical.com

Quadrupole Mass Spectrometers for Advanced Science

CATLAB Schematic

www.HidenAnalytical.com

Quadrupole Mass Spectrometers for Advanced Science

CATLAB Options • Corrosion resistant upgrade - includes upgrade of one gas flow line and corrosive gas resistant sample line seals, and a gas dilution/purge valve mass spectrometer pumping system. • Additional corrosion resistant feed lines if required.

• Additional 4 channel gas control unit integrated to provide 8 stream gas selection in total. • Option to choose the maximum flow of each MFCs. • Vapour Generation (gives vapour pressure equivalent to max liquid temperature ~30 °C). Other options available for higher flow rates. • 300 amu mass range option. Mass range to 1000 amu available for specialised applications

www.HidenAnalytical.com

Quadrupole Mass Spectrometers for Advanced Science

QIC Series Gas Analysers • 200 amu mass range, dual Faraday/ Electron Multiplier detector. • Detection capability from 100 % to 0.1ppm. • Fast scan speeds of100 amu/s.