How clean do assemblies have to be? [PDF]

Qualification standards. All standards for qualifying the cleanliness of as- semblies are listed below: · IPC J-STD-001

0 downloads 8 Views 2MB Size

Recommend Stories


How clean do assemblies have to be?
If you feel beautiful, then you are. Even if you don't, you still are. Terri Guillemets

[Read PDF] How to Be, Do, or Have Anything: A Practical Guide to Creative Empowerment Read
Ego says, "Once everything falls into place, I'll feel peace." Spirit says "Find your peace, and then

How to Clean Your Rigs
You often feel tired, not because you've done too much, but because you've done too little of what sparks

How old do you have to be to get into the horseshoe casino in cincinnati
It always seems impossible until it is done. Nelson Mandela

[PDF] Download How Not to Be Wrong
The only limits you see are the ones you impose on yourself. Dr. Wayne Dyer

[PDF] How Not to Be Wrong
How wonderful it is that nobody need wait a single moment before starting to improve the world. Anne

[PDF] How Not to Be Wrong
Life is not meant to be easy, my child; but take courage: it can be delightful. George Bernard Shaw

PDF Download How to be Heard
I cannot do all the good that the world needs, but the world needs all the good that I can do. Jana

PDF How Not to Be Wrong
You often feel tired, not because you've done too much, but because you've done too little of what sparks

Read PDF How Not to Be Wrong
In every community, there is work to be done. In every nation, there are wounds to heal. In every heart,

Idea Transcript


Important standards on qualifying the cleanliness of electronic assemblies

How clean do assemblies have to be? Dr. Helmut Schweigart, Oliver Manger, Zestron Europe, Ingolstadt, Germany

Many users are confronted with this question when assessing the cleanliness of their electronic assemblies. There is a wide range of standards, which deal with this issue and specify methods for analyzing the surface cleanliness by means of different processes. However, these days hardly any process engineer user has the time to get a general idea and understand all the standards relevant for their applications. For this reason, the most important standards on qualifying the cleanliness of electronic assemblies will be presented in the following.

· IEC – 68-2 is a standardized method for testing climatic reliability of electronic assemblies. · The GfKORR guidelines: “Leitfaden für An-

wendung und Verarbeitung von Schutzlacken“ (Guidelines for the use and processing of protective coatings) is a supplement to IPCHdbk-830 and helps to determine the coating reliability of assembly surfaces and geometries. As mentioned above, an extremely clean surface is particularly necessary prior to coating assemblies. Therefore, a wide range of standards specifying the degree of cleanliness for coated assemblies are available.

Standards and cleanliness requirements for coatings Three considerations must be taken into account to ensure the reliable coating of assemblies: Ionic contamination/residues from activators Resin residues and wettability of the surface Varnish hardening and reliability.

· · · Figure 1: Coating delamination

Various test methods for qualifying the cleanliness of assemblies are described in the standards. Since most test methods are very time-consuming and/ or costly to complete, this article additionally describes alternative test methods, which are inexpensive and can also be used for on-site sampling inspections.

When is high surface cleanliness required? To ensure that the coating or wire bond adheres permanently on assemblies, an extremely clean surface is required. Assemblies, which are exposed to critical, alternating climatic influences, require a very high surface cleanliness as well. Otherwise, malfunctions due to impurity-related leakage current and electrochemical migration can arise. Therefore, this article will focus on the following standards and associated test methods: Coating related standards Leakage current protection related standards Bonding processes related standards To provide a short overview, all industry qualifi-

· · ·

FROM EPP EUROPE SEPTEMBER/OCTOBER 2007

cation standards related to cleanliness qualification including coating, leakage current protection and bonding will be presented.

Qualification standards All standards for qualifying the cleanliness of assemblies are listed below: IPC J-STD-001, (chapter 8): ”Requirements for Soldered Electrical and Electronic Assemblies” describes the methods and requirements for electronic assembly manufacturing. IPC-A-610, (section 10.4): “Acceptability of Electronic Assemblies” is a visual documentation for specifying the quality requirements of electronic assemblies using best and worst cases. IPC TM 650: A collection of various test methods regarding electronic assemblies is summarized in IPC TM 650 “Test Methods Manual.” IPC TP 1113, (Technical Paper): “Circuit Board Ionic Cleanliness Measurement: What does it tell us?” describes the methods and limitations of the ionic contamination measurement and the influences of various flux systems.

Ionic contamination/residues from activators Hygroscopic residues such as activators in fluxes attract humidity from the surrounding air. This moisture can lead to the delamination of the protective coating due to the vapour permeability of the varnish (figure 1).

· · · ·

Test

Unit

Target value

Ionic contamination µg/cm2

< 0.4 µg/cm2

Surface tension

mN/m

> 40 mN/m

Zestron Flux Test



Residue-free

Zestron Resin Test



Residue-free

Polimerization inhibitors



Residue-free

Table 1: Parameters for the evaluation of the surface cleanliness prior to coating

Technical Center

Figure 3: Ionic contamination measurement; reliable coating not insured (> 0,4 µg NaCl Eq./cm²)

Similar to a showroom, the three technical centers provide over 35 cleaning machines of leading international equipment manufacturers for trials. Customers have the ability to get to know all common processes, such as ultrasonic, spray-in-air, spray-underimmersion and dip-tank applications, at one location!

lytical methods have been developed (such as the Zestron Flux Test), which selectively demonstrate the hygroscopic activator residues by means of a color reaction (figure 4). The Flux Test allows to reliably visualize the local distribution of residues directly on-site during production.

Resin residues Figure 2: Ionic contamination measurement process

In addition, electrolytes can occur, which trigger electrochemical migration. The initial qualification of cleanliness should be completed by visual inspection with 10 to 40 times magnification. Examples of visual cleanliness are shown in IPC-A-610: “Acceptability of Electronic Assemblies” under section 10.4. An indication of the presence of hygroscopic residues is provided by the measurement of ionic contamination and known as the sodium chloride equivalent (figure 2). This equivalent is generally determined in conformance with the IPC-TM-650 “Test Methods Manual,” number 2.3.25 using a 75 or 50 % 2-propanol/water solution. The evaluation is based on IPC J-STD-001D, 8.3.6.2. It should be noted that the indicated threshold of 1.56 µg NaCl Eq./cm² refers to ROL0 and ROL1 fluxes. Modern flux systems generate much less ionic contamination. For example, cleaned assemblies have a residual contamination of 0.1 to 0.4 µg NaCl Eq./cm² and 0.4 and 0.7 µg NaCl Eq./cm² for NoClean fluxes, due to the encapsulation of hygroscopic activators. The necessary requirement for reliable coatings is a contamination level < 0.4 µg NaCl Eq./cm² (figure 3). The measurement of ionic impurities does not permit any conclusion concerning the local distribution of these conductive contaminants. However, the precise distribution of the residues on the assemblies is extremely important when assessing the short or long-term potential hazard from these residues. Four years ago, the only option for detecting these impurities was to take a charge contrast image using a scanning electron microscope. Since this method is very time-consuming and expensive, it is not suitable for on-site monitoring during production. In the meantime, very easy-to-use ana-

An additional obstacle to reliable coating is the amount of resin residues on the assembly. If a protective coating is applied on top of the resin residues, wettability is impaired and adhesion insufficient. Due to the different expansion coefficients at temperature changes during operation, delamination or the formation of cracks in the coating can appear. The residual amount of resin is therefore specified in IPC J-STD-001D under section 8.3.6.1. For class 3 assemblies, a level < 40 µg/cm² is required, which approximately corresponds to the amount of resin on a single solder joint. In IPC-TM-650, section 2.3.27.1 an extraction method is used followed by HPLC (high performance liquid chromatography) to determine the amount of resin. Since this method is very time-consuming and expensive, it is not suitable for quick process control during production. A simple, quick and more economical method of demonstration is the Zestron Resin Test. This quick analytical test selectively demonstrates the presence of rosin and synthetic resin on assemblies by means of a color reaction. The analysis of surfaces for resin and activator residues as well as the determination of ionic cleanliness are hence the most important methods to ensure sufficient surface cleanliness for coatings. In addition to residues on the surface, the curing of varnish also plays an important role for the coating process. Different factors can prevent the varnish from curing and thereby make reliable coatings impossible. There are different test methods available to check the curing and reliability of the varnish.

Varnish hardening and reliability Depending on the varnish system, organic tin salts, which can arise as a reaction product from solder

Analytic Center ZESTRON´s Analytical Centers offer potential and current customers unrivalled possibilities for the evaluation and analytical inspection of assemblies and stencils. Various test methods for the surface cleanliness analysis of electronic assemblies according to international standards (i.e. IPC standards and J-STC 001D) are available. Additionally, the Analytical Centers are provided with equipments for ionic contamination, surface tension as well as contact angle measurement.

Visit us: ZESTRON Europe ...a Business Division of Dr. O.K. Wack Chemie GmbH Ingolstadt, Germany [email protected] www.ZESTRON.com

Test

Actual Target value value

Interference contrast



Uniform black coloration

Zestron Resin Test



Residue-free

Table 2: Parameters for the evaluation of the surface cleanliness prior to bonding

and fluxes, can act as polymerization inhibitors. Furthermore, sulfur and ammonia compounds, which are sometimes contained in fluxes, impair the curing of some coating systems. These impurities are generally identified by EDX using a scanning electron microscope. In this case, quick tests offer less costly alternatives. Various methods can be used to test the reliability of the coating after applying varnish. A complete life test can be performed according to IEC 68–2 standard. However, this test can only be performed after product development has been completed. In addition, the test duration of up to six months is still very time-consuming and expensive. A quick, cost-effective alternative, which can even be used in any stage of product development, is the so-called Coating Reliability (CoRe) Test. It is based upon the water immersion test described in the GfKORR “Guidelines for the Use and Processing of Protective Coatings”. By completely immersing the coated assembly in deionized water, the mechanism of electrochemical migration is strongly accelerated.

Therefore, conclusions concerning the reliability of the coating can be drawn within a few hours. However, not only assemblies with protective coatings have to function reliably. The requirements for leakage current protection must also be fulfilled without the applied coating. Therefore, standards for uncoated assemblies, which describe methods for analyzing the required surface cleanliness, are available.

Requirements for leakage current protection To prevent leakage current on assemblies (figure 5), there may not exist any residues, which lead to formation of electrolytes in conjunction with moisture. For this reason, the assembly should be visibly inspected and checked for hygroscopic compounds. Another important criterion for leakage current protection is the surface insulation resistance (SIR). This should be as high as possible to prevent signal distortion on the assemblies. The surface insulation resistance is usually determined by means of a SIR measurement according to IPC-TM-650, whereas only specified comb structures are used for evaluating or estimating the situation on the assembly. The threshold according to the standard is 108 ohm. In this case, the Flux Test described above can also be used as an easy method for estimating the potential danger of leakage current. Maximum surface cleanliness must also be achieved for wire bonding processes to ensure reliable bonds. Therefore all requirements relevant to surface cleanliness prior to bonding will be described in the following.

tion of electronic assemblies” (table 1). In a combined study with F&K Delvotec, Zestron has measured similar values for reliable bondability (table 2). By means of these quick and easily determinable parameters, reliable conclusions regarding the coatability and bondability of electronic assemblies can be drawn.

Conclusion If the described thresholds from the above standards are maintained, there will be no issues with leakage current protection and the reliability of coatings and wire bonds. To evaluate the cleanliness of electronic assemblies according to the standards, expensive and time-consuming test methods are not always necessary. By using the presented quick analytical tests, which can even be used on-site during production, reliable conclusions regarding surface cleanliness can be drawn. Zestron's specially trained process engineers offer support to qualify the surface cleanliness of assemblies at its Analytic Centers. www.zestron.com

Requirements for bonding processes

ZUSAMMENFASSUNG Der Beitrag stellt die wichtigsten Standards zur Qualifizierung der Sauberkeit elektronischer Baugruppen vor. Da allerdings die meisten der in den Standards beschriebenen Testmethoden sehr zeitaufwändig und/oder teuer sind, verweist der Beitrag zusätzlich auf alternative Testmethoden, die ebenfalls zur Probenentnahme während der Produktion verwendet werden können.

RÉSUMÉ La communication présente les principales normes de qualification de la propreté des blocs de composants électroniques. Cependant, la plupart des méthodes d'essai décrites dans les normes étant particulièrement longues et/ou coûteuses, la communication renvoie à des méthodes d'essai alternatives pouvant également être employées pour le prélèvement d'échantillons au cours de la production.

SOMMARIO L'articolo presenta gli standard di qualità più importanti sulla pulizia dei gruppi costruttivi elettronici. Poiché gran parte dei metodi di test previsti dagli standard richiedono molto tempo e/o sono costosi, l'articolo prende in considerazione anche metodi alternativi utilizzabili per il prelievo di campioni durante la produzione.

FROM EPP EUROPE SEPTEMBER/OCTOBER 2007

A visual inspection should also be made for bonding processes, which are mainly used with lead frames, DCB (direct copper bond) substrates or hybrids on FC (Flip-Chip) assemblies. The bonding process is primarily impaired by resin films and oxides on the bond pads. For example, resin can splash onto the bond pads during soldering. These resin residues lead to an insufficient wire bond since the bonds do not adhere properly on the residues. In addition, these impurities can reduce the adhesion of moulding materials. As described, time-consuming extraction methods and HPLC analyses or quick analytical tests can be used to demonstrate resin residues (figure 6). Another major requirement affecting the reliability of the bonds are intact and activated surfaces. Although surface activation is not a criterion specified in the standards, it represents an important variable for reliable bonds. To evaluate the oxidation status and check if metallically pure surfaces exist, the interference contrast is used. Metallically pure surfaces appear black and impurities, which could impair the bondability, can be identified.

Figure 4: Activator residues from soldering colored blue by the Flux Test

Figure 5: Conductive residues between two solder joints

Thresholds for reliable coatings and stable bonds Based on the provided criteria and empirical values with alternative test methods, parameters for the evaluation of reliable coatings were specified in the GfKORR working group “Corrosion protec-

Figure 6: Residues invisible (left) and visualized by the Resin Test (right)