IL-065 - Sensor heads | IL series | KEYENCE UK & Ireland [PDF]

Red semiconductor laser, wavelength: 655 nm (visible light) ... IP67. Pollution degree. 3. Ambient light. Incandescent l

7 downloads 31 Views 278KB Size

Recommend Stories


Today's UK & Ireland ratings
Keep your face always toward the sunshine - and shadows will fall behind you. Walt Whitman

PH2000 Series Power Heads
You miss 100% of the shots you don’t take. Wayne Gretzky

IKEA Delivery Addresses – UK & Ireland
Sorrow prepares you for joy. It violently sweeps everything out of your house, so that new joy can find

G4S Security Services UK & Ireland
Do not seek to follow in the footsteps of the wise. Seek what they sought. Matsuo Basho

Keyence Corp KYCCF
I want to sing like the birds sing, not worrying about who hears or what they think. Rumi

FTSE UK Index Series
Don't count the days, make the days count. Muhammad Ali

uk & ireland mortgage and property monthly
This being human is a guest house. Every morning is a new arrival. A joy, a depression, a meanness,

Installing the UK & Ireland Country Kit
Your task is not to seek for love, but merely to seek and find all the barriers within yourself that

A99B Series Temperature Sensor
Ego says, "Once everything falls into place, I'll feel peace." Spirit says "Find your peace, and then

Temperature Sensor 85026 Series
The happiest people don't have the best of everything, they just make the best of everything. Anony

Idea Transcript


easurement nsors

This site uses cookies to enhance your user experience. If you continue without changing your settings, we'll assume that you are happy to receive all cookies. Home

UK & Ireland

Home

Solutions

Products

Downloads

Measurement Sensors

Support

Overview

About Us

Laser Displacement Sensors (1D)

CMOS Multi-Function Analogue Laser Sensor

IL-065

My KEYENCE Careers

English

Products

Privacy

IL series

Contact Us

Models

All

Sign In

Register

+44(0)1908-696900 1-890-812-031

Input keywords

IL-065

IL series

Sensor heads

Other Models DOWNLOADS

Downloads

Catalogues Technical Guides

ser Displacement nsors (1D)

Download Catalogue

ser Profilometer (2D)



CAD Data

ptical Micrometer / gital Micrometer

Manuals

Data Sheet (PDF)

rface Scanning easurement Sensors onfocal)

Manuals

CAD Data

360°view (3D PDF) FOR YOUR SUPPORT

View Details

ductive Displacement/ auging Sensors

Ask KEYENCE

Dimensions

ontact Distance nsors / LVDT

Price Enquiry Request Demo / Test Free Trial Unit

SPECIFICATIONS

+44(0)1908-696900 1-890-812-031

Select Language English Model

IL-065

Reference distance

65 mm

Measurement range

55 to 105 mm

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*1 Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 550 x 1,750 µm

Linearity

±0.1% of F.S. (55 mm to 75 mm)*2*3

Repeatability

2 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Referenc e distance indicator: Red/Green LED

Temperature characteristics

0.06% of F.S./°C *3

Environmental resistance

MEASUREMENT LIBRARY

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 7,500 lux*5

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 75 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50. *2 Value when measuring the KEYENCE standard target (white diffuse object).

*3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm

*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-

300/IL-600, the sampling rate is 2 ms. *5 Value when the sampling rate is set to 2 ms or 5 ms.

LASER TECHNICAL GUIDE [An Introduction]

Dimensions

Data Sheet (PDF)

Overview

APPLICATION EXAMPLES of Microscope by industry Vol.1 Special Laser Marker Functions, Case Study [Using The Built-In Camera]

Other Models

Catalogues

Downloads:

LATEST / MOST DOWNLOADED

Technical Guides

CAD Data

View More

Manuals

Downloads

For visitors who viewed this page What is a sensor? Sensor Basics

Home

IL-065

Products



Measurement Sensors

Expert Solutions

Automotive Process Applications by Machine

Laser Displacement Sensors (1D)

IL series

Models

View More Models

+44(0)1908-696900 1-890-812-031

Price Enquiry

WEEE Directive RoHS Compliance Supplying to KEYENCE Sitemap

Copyright (C) 2018 KEYENCE CORPORATION. All Rights Reserved.

Certified Models

Privacy

Terms and Conditions

Terms of Use

Back to top

Smile Life

When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile

Get in touch

© Copyright 2015 - 2024 PDFFOX.COM - All rights reserved.