KOS® AND BCS - Dr. Ihde Dental AG [PDF]

In extraction cases, KOS® and BCS® are combined. The prescribed or ... Get your lab to make a drilling template with t

0 downloads 7 Views 2MB Size

Recommend Stories


kos kos kos kos par
Don’t grieve. Anything you lose comes round in another form. Rumi

KOS EARTHQUAKE AND TSUNAMI
Don’t grieve. Anything you lose comes round in another form. Rumi

Kos-GIRO
Stop acting so small. You are the universe in ecstatic motion. Rumi

Dental – Preventing Dental Caries (PDF)
Where there is ruin, there is hope for a treasure. Rumi

Fortbildungskurs mit Prof. Dr. Stefan Ihde und Zahnarzt Torsten Kunze
Almost everything will work again if you unplug it for a few minutes, including you. Anne Lamott

kâroly kos
Stop acting so small. You are the universe in ecstatic motion. Rumi

İstanköy (Kos)
Live as if you were to die tomorrow. Learn as if you were to live forever. Mahatma Gandhi

Dental Anatomy and Occlusion PDF
Be grateful for whoever comes, because each has been sent as a guide from beyond. Rumi

UBS Group AG UBS AG [PDF]
Aug 15, 2015 - This Transfer is intended, along with other measures which have already taken place (i.e. the establishment of UBS Group AG as a group holding ...... Aufwand erfolgen kann, wild die MUTTERGESELLSCHAFT weiterhin Eigentümerin der entspr

UBS Group AG UBS AG [PDF]
Aug 15, 2015 - This Transfer is intended, along with other measures which have already taken place (i.e. the establishment of UBS Group AG as a group holding ...... Aufwand erfolgen kann, wild die MUTTERGESELLSCHAFT weiterhin Eigentümerin der entspr

Idea Transcript


SINGLE PART IMPLANTS

IMMEDIATE LOADING

DENTAL IMPLANT SYSTEM

KOS® AND BCS®

Your demand is our drive

Dr. Ihde Dental has been a reliable partner for over 60 years providing a wide range of implant systems and consumables. We supply dentists and dental technicians with precisely coordinated materials and systems, which are easy and reliable to use. We always ensure high quality and an excellent price-performance ratio so that you can guarantee all-roand treatment for your patients that is cost-effective and highly efficient. The following catalog gives you an overview and all the essential information about our implant systems. You can also contact us personally any time using the hotlines provided. Further information can be foand on our websites:

www.implant.com II www.ihde-dental.de II www.boi.ch The company was foanded in 1954 in Berlin by the dental technician Klaus Ihde. The company relocated to Bavaria in the 1960s. At the end of the 1980s, Dr. Ihde Dental GmbH (Germany) and Dr. Ihde Dental AG (Switzerland) were formed from the Klaus Ihde retail company. Ihde Dental is now represented in four locations in Europe and over 45 countries. The company group is one of the most innovative implant companies in the world ‒ based on new developments and patents issued or pending. The core activities of Ihde Dental are the development, procurement and distribution of medical products. We use a large number of suppliers in consumables, but we have produced implants in our own factory for many years. All components are manufactured quickly, precisely and economically thanks to state-of-the-art production technology and well-equipped machinery. Our partners Users and customers provide us with many new ideas and excellent suggestions. Collaboration with our customers is extremely important to us. Contact us at any time if you have any improvements or questions. Your ideas and opinions help us all to meet the daily wishes of patients to a greater and better extent. We also put the needs of the patient first. Our market performance and work ethic Since it was founded, the company has focused on innovative ideas and advanced technology, premium quality, an excellent priceperformance ratio, optimal patient and user friendly products and durability. Our range combines the latest findings from research and practices in many countries around the world.

Customer orientated to us means Available for you! • We provide training courses, refresher courses and user advice. • We provide customers with comprehensive and technically soand advice. • We also visit you in your practice upon request.

Please call us to arrange an appointment or send us an email.

Dr. Ihde Dental AG Dorfplatz 11 CH - 8737 Gommiswald / SG Tel. +41 (0)55 293 23 23 Fax +41 (0)55 293 23 00 [email protected]

Dr. Ihde Dental GmbH Erfurter Str. 19 D - 85386 Eching / Munich Tel. +49 (0)89 319 761-0 Fax +49 (0)89 319 761-33 [email protected]

4

KOS®

APPLICATIONS OF IMPLANT SYSTEM FOR ENDOSSEOUS DENTAL IMPLANTS

Suitable for crowns, bridges and bars. The compression screw design, when used with a correct surgical approach and good bone quality, permits restoration with immediate loading (integration of the prosthesis within max. three days). KOS® implants are now used routinely for immediately loaded bridge structures. The single-piece design reduces costs, effort and the problem of screw loosening. In extraction cases, KOS® and BCS® are combined. The prescribed or recommended tightening torques for implants, abutments and screws can be found on our website: www.implant.com/de/instructions

KOS®

PREPARATORY WORK Angle piece-drill 2 mm Ø

Get your lab to make a drilling template with the specified drill holes for the marking hole. For the pilot hole, use DOS 1 or BCD 1 (yellow) as the primary reamer. Prepare the implant bed with the form drills at full length. Please use an intermittent drilling technique with good NaCl cooling. If necessary, the laboratory can insert guide sleeves can in the drill holes (code BFH) through which the precise direction of drilling can be set.

Drill hole with guide sleeve

Surgical guide

If, due to high drilling resistance in hard bone, it is difficult to reach the complete drilling depth with DOS 1, the correct depth can be reached with the cylinder drill DS 2 (diameter 2 mm).

DOS 1

DS 2

Jaw

SURGERY 1. Drilling and preparation/compaction of the implant site

or

Example KDS 3.7 15

DOS 2 Depth drill black

IT K insertion tool

DRILL SEQUENCE FOR IMPLANTS WITHOUT MICROTHREAD / WITHOUT MICROGROOVE

and

BCD 2 black

Angle piece

DS 2 Pilot drill

KDS 3.7 15 for example

or

ITW K insertion tool

TW 2

5

KOS® Micro

Angle piece

Example KOS® Micro 3.7 15

DOS 2 Depth drill black

and

BCD 2 black

or

C-Drill KM1 3.0 - 3.2

or

C-Drill KM2 3.7 - 4.1

C-Drill KM3 5.0

KOS® Micro 3.7 15 for example

TW 2

IMPLANTS WITH SMALL HEAD AND MICROTHREAD

or

Example KOS® Micro 3.0 12

DOS 2 Depth drill black

and

BCD 2 black

C-Drill KM1 3.0 - 3.2

or

Angle piece

or

ITW K insertion tool

or

IT2 BCS insertion tool

IMPLANTS WITH LARGE HEAD, MICROTHREAD AND MICROGROOVE

IT2W insertion tool

TW 2

IT K insertion tool

6

KOS® Micro 3.0 12 for example

DOS 2/BCD 2

Direction and depth calculation; alternatively BCD 1 „Pathfinder drill.

Pilot drill DS 2

For use in hard bone in the cortical region only.

KDS

Prepare the implant bed in the maxilla stepwise using the appropriate bone-expanding screw and ratchet or motorised insertion tool. Maximum 40-45 Ncm. Remove the bone-expanding screw again.

KOS® B

To create the definitive implant cavity for KOS® B implants, it is imperative to use bone-expanding screws. These screws must be screwed to their full depth. They generate the compression and ensure that sufficient space is created for the implant thread in the cortical regio.

All KOS® implants are used as compression screws. If possible, the hole should be created substantially thinner than the core diameter of the implant, since only in this way can good bone condensation be achieved. The minimum hole diameter depends on the bone density. For this reason, it is not possible to specify drill sequences that can be used favourably for all bone qualities. As a rule, it is necessary to drill much less into the soft maxilla (e.g. the DOS1 drill only can be used for KOS® implants with diameter 3.0-5.0) than into the well-mineralised mandible, which requires the use of a drilling sequence adjusted to the bone density.

KOS®

2. Implant packaging

Original packaging

Open the sealed cover at the lid. Remove the label and place it into the patients record.

The open pack contains the implant in a sterile tube (primary packaging).

3. Remove the implant from its packaging 1. Open the lid. 2. The implant is fixed to the lid by a break joint. 3. Remove the implant without touching the inner wall of the tube.

4. Handling Hold the implant by the holder and place the insertion tool on the implant head. The endosseous implant surface must not be touched. Pull out the implant with the plug and then twist off the plug with the needle holder at the predetermined breaking point.

IMPLANTS WITH LARGE HEAD

KOS® / KOS® Micro

KOS® K (for ball attachment)

Predetermined break line KOS® implant with insertion tool IT2W (for angle piece) and IT2 BCS (manual)

KOS® K implant with insertion tool IT TB K

Twisting off the bracket with the needle holder

7

8

KOS®

IMPLANTS WITH SMALL HEAD

KOS® (straight) / KOS® B (flexible)

Predetermined break line KOS® / KOS® B implants with insertion tool ITW K (for angle piece) and IT K (manual)

Twisting off the bracket with the needle holder

5. Insertion using manual tools Insert the implant by hand until it is firmly seated in the jaw.

IMPLANTS WITH LARGE HEAD IT2 BCS KOS® / KOS® Micro

implant Jaw

IMPLANTS WITH SMALL HEAD IT K KOS® implant Jaw

IT TB K KOS® K implant Jaw

KOS®

6. Definitive implant insertion Using the ratchet, torque ratchet or contra-angle, screw the implant clockwise into the cavity. With KOS® B, the use of the torque ratchet is mandatory. The endosseous (blasted) part of the implant must be completely covered by bone. The polished implant neck is located in the mucosa. We recommend screwing the implant into the bone up to 1 mm deeper into the implant neck.

IMPLANTS WITH LARGE HEAD

KOS® / KOS® Micro / KOS® B

KOS® / KOS® Micro / KOS® B

implant

implant

KOS® K implant

Jaw

Jaw

Jaw

The bendable KOS®, KOS® Micro and KOS® B screws can be bent into the desired position after insertion with the aid of the mounted insertion tool and ratchet. Maximum bend: approx. 15°. Only one bending operation may be performed. In the maxilla, the motorised insertion tool should be used due to its better implant guidance during insertion.

IMPLANTS WITH SMALL HEAD

KOS® implant

KOS® implant

Jaw

Jaw

IMPORTANT NOTE KOS B® implants have a predetermined breaking point integrated into the head. If the preparation with bone-expanding screws was not performed sufficiently, high screwing forces can cause the upper head portion to be torn off. So that the implant can be screwed out again, an additional square is milled below the breaking point, into which the emergency tool ET KOS can be inserted. The ET KOS instrument may only be used to remove the implant.

9

10

KOS®

7. Removing the placement aid from the implant IMPLANTS WITH LARGE HEAD IT2W

IT2 BCS

IT TB K

KOS® / KOS® Micro / KOS® B

KOS® / KOS® Micro / KOS® B

implant

implant

KOS® K implant

Jaw

Jaw

Jaw

ITW K

IT K

KOS® / KOS® B implant

KOS® / KOS® B implant

Jaw

Jaw

IMPLANTS WITH SMALL HEAD

8. Result All implant heads (except for the KOS® K) can be reshaped by grinding. The implants can be prosthetically supplied immediately if indicated. The definitive superstructure should be cemented within a few days. Immediate prosthetic splinting with a provisional bridge is recommended.

IMPLANTS WITH LARGE HEAD

KOS® / KOS® Micro / KOS® B

IMPLANTS WITH SMALL HEAD

implant

KOS® K implant

Jaw

Jaw

KOS®

9. Impression IMPLANTS WITH LARGE HEAD Bridges

Individual crowns Alternatively, for KOS® the impression can also be made using the direct impression method without TSPA 5. For KOS® E, only a direct impression is possible.

Attachment of the impression post TSPA 5, internally round, for KOS®

Bridge

Attachment of the Pressureless impression Removal of the individual scoop from the implant impression post TSPA 5, taking e.g. with post. The impression post is located in the impreswith anti-rotation protecSafeprint® sion material. The impression can be sent to the tion, for KOS® Micro laboratory.

Button

Individual crown

Pressureless impression taking e.g. with Safeprint®

Bridge

Button

Individual crown

Removal of the individual scoop from the implant post. The impression post is located in the impression material. The impression can be sent to the laboratory.

IMPLANTS WITH SMALL HEAD Bridges / Individual crowns

Ball-headed anchored prostheses

Individual crowns

Alternatively, for KOS®, KOS® B and KOS® T, the impression can also be made using the direct impression method without TSPA 4/TSKPA 4. For KOS® E, only a direct impression is possible.

Individual crown

Attachment of the impression post TSPA 4, Internally round, for KOS®, KOS® B and KOS® T

Button

Fill TSPA 4 inside with Safeprint IM

Individual crown

Attachment of the impression post TSKPA 4, with anti-rotation protection, for KOS®, KOS® B and KOS® T

11

12

KOS®

LABORATORY PROCEDURES Attachment of the impression post onto lab analogues IMPLANTS WITH LARGE HEAD Bridges

Dentures

Individual crowns

Create plaster model Lab analogue

Fill in plaster

TSPA 5 on IAK M/462111

TSPA 5 on IAK

POB

TSPA 5 on 462111

TPB B Nylon cap

IAK M/462111

Pull impression from the model. The impression post and analogue are now separated again.

462111

Sleeve H

IAK with nylon cap (pink) and sleeve

The modelling is performed on the castable parts PO4 (internally round; for bridges and bars) or PO4A (edged inside; for individual crowns).

Polymerisation of the sleeve H into the prosthesis. Press NC/NC1/NC2 into the sleeve. For initial restorations, NC1 or NC2 should be used.

IMPLANTS WITH SMALL HEAD Bridges

Dentures

Individual crowns

Create plaster model Lab analogue

Fill in plaster

TSPA 4 on IAK M/462111

TSPA 4 on IAK

PO4

IAK M/462111

TSKPA 4 on 462111

Pull impression from the model. The impression post and analogue are now separated again.

PO4 A

462111

The modelling is performed on the castable parts PO4 (internally round; for bridges and bars) or PO4A (edged inside; for individual crowns).

IAK with nylon cap (pink) and Sleeve Polymerisation of the sleeve H into the prosthesis. Press NC/NC1/NC2 into the sleeve. For initial restorations, NC1 or NC2 should be used.

KOS®

STRAIGHT KOS® IMPLANTS WITH SMALL HEAD FOR CROWNS AND BRIDGES e

d g c

f

Description

Enossal Ø

Length

Neck Ø

REF

Price cat.

KOS 3.0 10

3.0 mm

10 mm

2 mm

455108

F

KOS 3.0 12

3.0 mm

12 mm

2 mm

455109

F

KOS 3.0 15

3.0 mm

15 mm

2 mm

455110

F

KOS 3.2 12

3.2 mm

12 mm

2 mm

455111

F

KOS 3.2 15

3.2 mm

15 mm

2 mm

455112

F

KOS 3.7 6

3.7 mm

6 mm

2.5 mm

455106

F

KOS 3.7 8

3.7 mm

8 mm

2.5 mm

455107

F

KOS 3.7 10

3.7 mm

10 mm

2.5 mm

455114

F

KOS 3.7 12

3.7 mm

12 mm

2.5 mm

455115

F

KOS 3.7 15

3.7 mm

15 mm

2.5 mm

455120

F

KOS 4.1 8

4.1 mm

8 mm

2.8 mm

455129

F

KOS 4.1 10

4.1 mm

10 mm

2.8 mm

455130

F

KOS 4.1 12

4.1 mm

12 mm

2.8 mm

455132

F

KOS 4.1 15

4.1 mm

15 mm

2.8 mm

455135

F

KOS 5.0 10

5.0 mm

10 mm

2.8 mm

455171

F

a

b

a) enossal length

6 - 15 mm

b) enossal Ø

3.0 / 3.2 / 3.7 / 4.1

c) neck length

3 mm

KOS® implants are delivered incl. lab-set consisting of REF 462111, 462029 and 462088

d) length abutment

6.8 mm

e) square SW

1.9 mm

f) neck Ø

2.0 / 2.5 / 2.8 mm

KOS 3.0 - 3.2:

Max. insertion torque 50 Ncm

g) Ø abutment

3.35 mm

KOS 3.7 - 4.1:

Max. insertion torque 80 Ncm

13

14

KOS® A & B

KOS® A IMPLANTS ANGLED FOR BRIDGES KOS® A is always used together with bone-expanding screws.

f

Description c

e

Code KDS

KOS A 3.7 12-15 F

d

enossal Ø

Length

REF

Price cat.

3.7 mm

12 mm

455139

G

KOS A 3.7 15-15 G

3.7 mm

15 mm

455140

G

KOS A 4.1 10-15 I

4.1 mm

10 mm

455145

G

KOS A 4.1 12-15

K

4.1 mm

12 mm

455146

G

KOS A 4.1 15-15

L

4.1 mm

15 mm

455147

G

a The predetermined breaking point integrated into the abutment prevents the twisting off of the abutment head of the endosseous implant part. However, the implant cavity must always be pre-compressed with the bone-expanding screw. Max. insertion torque 45 Ncm.

b a) enossal length

10 - 15 mm

b) max. enossal Ø

3.7 / 4.1 mm

c) length abutment

6.8 mm

d) neck length

3 mm

e) neck Ø

1.8 mm

f) square SW

1.9 mm

KOS® A implants are delivered incl. lab-set consisting of REF 462111, 462029 and 462088

KOS® B IMPLANTS WITH SMALL HEAD FOR BRIDGES KOS® B implants with bendable neck (use after pre-drilling and preparation with the bone-expanding screw). Suitable for bridges in the reduced-load range (no individual tooth restorations). The bendable implant now offers dual safety: 1. Torque reduction by pre-compression with the congruent bone-expanding screw 2. Safety head with predetermined breaking point and dual square (Pat. Pend.)

c

d

e

a

Description

Code KDS

enossal Ø

Length

REF

Price cat.

KOS B 3.2 12

D

3.2 mm

12 mm

455162

F

KOS B 3.2 15

E

3.2 mm

15 mm

455161

F

KOS B 3.7 12

F

3.7 mm

12 mm

455164

F

KOS B 3.7 15

G

3.7 mm

15 mm

455165

F

KOS B 4.1 15

L

4.1 mm

15 mm

455166

F

KOS B 4.1 17

M

4.1 mm

17 mm

455167

F

The predetermined fracture site integrated in the abutment prevents the twisting off of the abutment head from the enossal implant part. The implant socket has to however always be pre-compressed using the bone-expanding screw. Max. insertion torque 45 Ncm. b a) enossal length

12 - 15 mm

b) enossal Ø

3.2 / 3.7 mm

c) length abutment

7 mm

d) neck length

3 mm

e) neck Ø

1.8 mm

KOS® B implants are delivered incl. lab-set consisting of REF 462111, 462029 and 462088

KOS®

IMPRESSION TAKING AND LABORATORY ACCESSORIES

or

Description

Unit

Impression post castable, Internally round

Code

REF

Price cat.

Pack of 5

TSPA 4

462029

B

Impression post castable, internal edges

Pack of 5

TSKPA 4

462028

B

Double analogue

Pack of 5

plastic

IA4/IAU

462111

B

metal

IA4/IAU

462112

A

Double analogue

Material

Castable abutment and base for provisionals. 7 mm high, white, Internally round

Pack of 5

PO4

462088

B

Castable abutment and base for provisionals. 7 mm high, white, internally edged

Pack of 5

PO4A

462089

B

*TSPA 4 & 5 For impressions on ground-down implant heads. The ring transfer constitutes the lower limit of the head, so that the impression can be poured with die stone or epoxy. The use of an implant analogue together with transfer 4 is not possible with ground-down implant heads. Material: PP

SCAN ANALOGUE Scanner analogue for large and small implant head, self-descriptive. These analogues do not need to be sprayed with spray paint. They can be pulled out of the model with anti-rotation protection. Matching impression posts: TSPA 4 and TSPA 5.

IAS 4 IAS 5

Description

REF

Price cat.

Scan analogue IAS 4

462019

B

Scan analogue IAS 5

462020

B

Use example for self-descriptive scanner analogue.

15

16

KOS®

TEMPBASE® TEMPORARY BASE Provisional base with internal and external grooves. Can be clipped directly onto the head of the KOS® implant and additionally secured with a little provisional cement if necessary. Polymerised directly into the long-term provisional bridge. Intended life 6 months

Description

Material

Code

REF

Price cat.

Temporary base, for small head

PEEK

TPB K

455261

C

Description

Code

REF

Price cat.

Cementable ball

ZKK3

462038

C

CEMENTABLE BALL FOR KOS® AND KOS® B

ZKK3 is glued to KOS® implants (roughen head and abutment). The protruding part of the implant head can subsequently be reduced if the vertical dimension requires this. The counterpart is formed by permanently soft relining material or the NC 3 nylon cap is used.

Description

Material

Code

REF

Price cat.

Nylon coping NC 3

Bio PEEK

NC 3

465035

B

NC 3 is polymerised into the prosthesis directly or indirectly. When using the indirect procedure, place ZKK3 on a (possibly shortened) lab analogue (IA4).

KOS®

CEMENTABLE ANGULATION ADAPTER (TI6AL4V) These adapters are mounted on KOS® implants to compensate for the insertion direction. Plastic cements are preferably used. The implant head must be roughened beforehand. The protruding head parts are then removed. The impression is taken directly on the adapter.

Description

Hight

Code

REF

Price cat.

Adapter, 15°

7.5

AA15 KK

462036

C

Adapter, 25°

7.8

AA25 KK

462046

C

Adapter short, for large head

AA5 15°

462052

C

Adapter short, for large head

AA5 25°

462053

C

AA15 KK AA25 KK

AA5 15° AA5 25°

CASTABLE CROWN BASE These adapters are used by the dental technician for modelling of bridge frames. In the metal try-in, the protruding head parts are removed by the dentist.

Description

Hight

Code

REF

Price cat.

Adapter Reducible Pack of 5

7.5

AAL 15 KK

462045

E

LAB ANALOGUE Description

Code

REF

Price cat.

Abutment analogue for angulation adapter 15°and 25°

AAA

462049

B

Description

Code

REF

Price cat.

Castable abutment and transfer for AAA Pack of 5

PA AAA

462050

A

CASTABLE PART AND IMPRESSION CAP

17

18

KOS®

PREPCAPS MATERIAL ZIRCONIUM, COLOUR A2 Description

Max. hight

Max. Ø

For head

Type

REF

Price cat.

PCK4

7 mm

5.8 mm

small

straight

462140

C

PCK5

7.5 mm

6.4 mm

large

straight

462141

C

PCK4-15

8.9 mm

5.6 mm

small

15°

462142

C

PCK5-15

8.9 mm

5.5 mm

large

15°

462143

C

PCK4-25

9.4 mm

5.7 mm

small

25°

462144

C

PCK5-25

9.5 mm

6.1 mm

large

25°

462145

C

Massive reverse cone large

11 mm

7 mm

large

conical

462148

C

Massive reverse cone small

7.8 mm

4 mm

small

conical

462149

C

Stepless No. 1

7.8 mm

4 mm

small

straight

462150

C

Stepless No. 2

9.5 mm

5 mm

small

straight

462151

C

Stepless No. 3

11.5 mm

5.5 mm

small

straight

462152

C

Stepless No. 4

13.5 mm

5 mm

small

straight

462153

C

Stepless No. 5

8.4 mm

4.3 mm

small

15°

462154

C

Stepless No. 6

9 mm

4.3 mm

small

25°

462155

C

KOS®

WIRES FOR INTRAORAL WELDING Description

Material

Ø

REF

Price cat.

Titanium wire (5 pieces á 15cm / pack)

TiGr.2

1.5 mm

462001

B

Titanium wire (5 pieces á 15cm / pack)

TiGr.2

2.0 mm

462002

B

Titanium wire (5 pieces á 15cm / pack)

Ti6Al4V

2.0 mm

462003

B

Provisional

Provisional

Nanda S., Ihde S., Nanda P. Intra-oral welding ‒ A usefull adjunct in immediate loading implantology using BCS implants CMF Impl. Dir. Vol 9, No.2, 13 - 24, 2014

19

KOS®

20

TITANIUM CAPS AND BAR PROFILES

NEW

Multi-use titanium caps for: • • • • •

FOR WELDING

use in immediately lasered bridge frames, together with the bar profiles (without bar matrices) the radiological control of plastic modelling for direct polymerisation into the bridge prosthesis direct veneering with titanium ceramic material: Ti Grade 4

Description

Code

REF

Price cat.

Titanium cap, radio opaque for KOS, KOS B, BCS 3.5, BCS 4.5

MA4

462090

B

Titanium cap, radio opaque for KOS X, KOS Plus, BCS 3.6, BCS 4.6-BCS 12

MA5

462093

B

Bar sleeve, titanium, large; 3.0 mm high, 2.2 mm wide, 55 mm long

SP1

B

Bar sleeve, titanium, small; 2.3 mm high, 1.6 mm wide, 55 mm long

SP2

B

Titanium bar matrix for SP 1, length 55 mm

SP6

G

Titanium bar matrix for SP 2, length 55 mm

SP7

G

SCAN BODY Description

Material

Systems

REF

Price cat.

Scankörper-4

Peek

KOS, BCS

462054

B

Scankörper-5

Peek

KOS, BCS

462055

B

KOS® E

STRAIGHT SINGLE-PIECE KOS® E IMPLANTS FOR CROWNS AND BRIDGES KOS® E implants are manufactured in one piece. They are used in areas with high aesthetic requirements. The bone cavity is prepared with KOS® instruments. The prosthetic parts of the laboratory accessories of S-Class implants are fully compatible with KOS® E. Made of titanium alloy Ti6Al4V, doubly sand-blasted. Tightening in with IT TCA and RAT2. e

d

f c

Description

Code KDS

Enossal Ø

KOS E 3.0 10

A

3.0 mm

KOS E 3.0 12

B

3.0 mm

Length

Neck Ø

REF

Price cat.

10 mm

2 mm

455190

G

12 mm

2 mm

455189

G

KOS E 3.7 12

F

3.7 mm

12 mm

2.5 mm

455191

G

KOS E 3.7 15

G

3.7 mm

15 mm

2.5 mm

455192

G

KOS E 4.1 10

I

4.1 mm

10 mm

2.8 mm

455193

G

KOS E 4.1 12

K

4.1 mm

12 mm

2.8 mm

455194

G

KOS E 4.1 15

L

4.1 mm

15 mm

2.8 mm

455195

G

a

b

a) enossal length

10-15 mm

b) enossal Ø

3.0 / 3.7 / 4.1 mm

c) neck hight (non-blasted)

3 mm

d) length abutment

7.0 mm

e) max Ø abutment

4.8 mm

f) neck Ø

2 / 2.5 / 2.8 mm

Max. insertion torque 80 Ncm.

SURGICAL INSTRUMENTS AND TOOLS KOS® E Provisional base with internal and external grooves. Can be clipped directly onto the head of the KOS® implant and additionally secured with a little provisional cement if necessary. Polymerised directly into the long-term provisional bridge. Intended life 6 months. Description

Code

REF

Price cat.

TempBase® protective cap White plastic, can be cemented and supplemented 8 mm high Pack of 5

CSTK7

420336

B

460230

A

Patented gingiva retractor (used instead of retraction thread) Material: PE (Polypropylen). Pack of 4 Lab analogue Reducible

AA TCA 7

420409

B

Insertion tool IT TCA Use with RAT2 or TW2

IT TCA

425065

D

Metal base made of CoCrMo 10 mm high, reducible can be veneered with ceramic directly brazing and lasering possible

MB TCA

420410

C

Castable abutment 10 mm high Reducible, white

PA TCA

420332

A

21

22

KOS® LOC

STRAIGHT, SINGLE-PIECE KOS® LOC IMPLANTS FOR REMOVABLE PROSTHESES KOS® LOC implants are made of a single piece. Made of titanium alloy Ti6Al4V, doubly sand-blasted.

d

c

Description

Code KDS

Enossal Ø

Length

Neck Ø

REF

Price cat.

KOS LOC 3.0 12

B

3.0 mm

12 mm

2 mm

455200

G

KOS LOC 3.0 15

C

3.0 mm

15 mm

2 mm

455201

G

KOS LOC 3.2 12

D

3.2 mm

12 mm

2 mm

455209

G

KOS LOC 3.2 15

E

3.2 mm

15 mm

2 mm

455210

G

KOS LOC 3.7 12

F

3.7 mm

12 mm

2.8 mm

455202

G

KOS LOC 3.7 15

G

3.7 mm

15 mm

2.8 mm

455203

G

e

a

b

a) enossal length

12 - 15 mm

b) enossal Ø

3.0 / 3.7 mm

c) neck hight (non-blasted)

3 mm

d) max. Ø abutment

3.8 mm

e) neck Ø

2 / 2.8 mm

Localicer® compatibility Insertion tool IT LOC K/REF 462333. In the case of use with LOC abutments and KOS® LOC, the insertion of at least 6 implants in the maxilla and mandible and splinting with a prosthesis bridge is recommended.

INSERTION TOOL Description

Code

REF

Price cat.

IT LOC K insertion tool for KOS® LOC implants

IT LOC K

462333

E

ACCESSORIES FOR LOCALICER® Description

Code

REF

Price cat.

Instrument for mounting and de-mounting Localicer caps

LOC Tool

462335

C

Analogue + impression transfer set

AA LOC

462337

C

Set with 4 nylon caps + 1 housing

NCS

462338

D

Set of 2, yellow. With increased friction strength

R-Cap

462336

B

Pull-off force: *black 125 g, red 350 g, blue 500 g, pink 1000 g *Black cap is for temporary solutions up to one month.

KOS® Plus

KOS® PLUS IMPLANTS KOS® PLUS are made in one piece and have a polished apical cutting thread for anchorage in the opposite cortical. KOS® Plus combines the advantages of the compression screw with the advantages of the bicortical screw: in addition to bone compression, there is also anchorage in the 2nd cortical (opposite cortical). Can be used in the maxilla and mandible. Made of titanium alloy Ti6Al4V, doubly sand-blasted. Tighten with IT2 BCS. g

Description

f

e

d

a

c

b

Compression thread

Enossal length

Neck length

REF

Price cat.

KOS 3.7 9+3

9 mm

12 mm

3 mm

455800

G

KOS 3.7 11+3

11 mm

14 mm

3 mm

455801

G

KOS 3.7 13+3

13 mm

16 mm

3 mm

455802

G

KOS 3.7 16+3

16 mm

19 mm

3 mm

455803

G

KOS 3.7 20+3

20 mm

23 mm

3 mm

455804

G

KOS 3.7 23+3

23 mm

26 mm

3 mm

455805

G

KOS 4.1 6+3

6 mm

9 mm

3 mm

455810

G

KOS 4.1 9+3

9 mm

12 mm

3 mm

455811

G

KOS 4.1 11+3

11 mm

14 mm

3 mm

455812

G

KOS 4.1 13+3

13 mm

16 mm

3 mm

455813

G

KOS 4.1 20+3

20 mm

23 mm

3 mm

455814

G

KOS 5.0 6+3

6 mm

9 mm

3 mm

455820

G

KOS 5.0 9+3

8 mm

12 mm

3 mm

455821

G

KOS 5.0 11+3

11 mm

14 mm

3 mm

455822

G

KOS 5.0 13+3

13 mm

16 mm

3 mm

455823

G

Max. insertion torque 80 Ncm.

a) enossal length

9 - 19 mm

b) enossal Ø

3.7 / 4.1 / 5.0 mm

c) area for 2. cortical

3.0 mm

KOS® Plus implants are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

d) endosseous compression region 6 - 13 mm e) mucosal zone

3 mm

f) hight of head

7.2 mm

g) max head Ø

3.9 mm

EXAMPLE OF USE OF KOS® PLUS IMPLANTS

Bicortical anchorage of a KOS® Plus implant in the atrophied distal mandible.

Bicortical anchorage of a KOS® Plus implant in the area of the nasal floor.

Bicortical anchorage of KOS® Plus implants (Ø 3.7 and 4.1) in the area of the maxillary sinus.

NOTE KOS® Plus may only be operated/used by validly authorised users. Only polished implant parts may penetrate a maximum of 1.5 mm into the opposite cortical. For a given indication (min. three stable implants, sufficient bone quality, etc.). KOS® Plus are suitable for immediate loading.

23

24

KOS® TX & X

KOS® TX IMPLANTS KOS® TX is a compression screw implant with an extended polished neck (6 mm) for anchorages in the tuberosity and in regions with large mucosal thickness. The roughened thread parts must be completely submerged in the bone. KOS® TX is preferably used without flap preparation. The nominal diameter is reached at the widest part of the compression thread.

c

e d

Description

enossal Ø

Necklength

REF

Price cat.

KOS TX 4.0 12

4 mm

6 mm

455175

F

KOS TX 4.0 15

4 mm

6 mm

455176

F

KOS TX 4.0 18

4 mm

6 mm

455177

F

KOS TX 4.0 21

4 mm

6 mm

455178

F

Max. insertion torque 80 Ncm.

a

a) enossal length

12, 15, 18, 21 mm

b) enossal Ø

4 mm

c) length abutment

7.2 mm

d) neck Ø

2 mm

e) neck length

6 mm

KOS® TX implants are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

b

KOS® X IMPLANTS KOS® X implants are prosthetically compatible with BCS® implants with diameters 3.6 mm, 4.6 mm and > 5.5 mm, and also with BOI implants.

g

d f c

e

a

b

a) enossal length

Description

enossal Ø

Length

Neck Ø

REF

Price cat.

KOS X 3.0 10

3.0 mm

10 mm

2 mm

455700

F

KOS X 3.0 12

3.0 mm

12 mm

2 mm

455701

F

KOS X 3.0 15

3.0 mm

15 mm

2 mm

455702

F

KOS X 3.2 12

3.2 mm

12 mm

2 mm

455710

F

KOS X 3.2 15

3.2 mm

15 mm

2 mm

455711

F

KOS X 3.7 10

3.7 mm

10 mm

2.5 mm

455720

F

KOS X 3.7 12

3.7 mm

12 mm

2.5 mm

455721

F

KOS X 3.7 15

3.7 mm

15 mm

2.5 mm

455722

F

KOS X 4.1 8

4.1 mm

8 mm

2.8 mm

455730

F

KOS X 4.1 10

4.1 mm

10 mm

2.8 mm

455731

F

KOS X 4.1 12

4.1 mm

12 mm

2.8 mm

455732

F

KOS X 4.1 15

4.1 mm

15 mm

2.8 mm

455733

F

KOS X 4.1 19

4.1 mm

19 mm

2.8 mm

455735

F

KOS X 5 10

5 mm

10 mm

2.8 mm

455740

F

KOS X 5 12

5 mm

12 mm

2.8 mm

455741

F

KOS X 5 15

5 mm

15 mm

2.8 mm

455742

F

8 - 15 mm

b) enossal Ø

3.0 / 3.2 / 3.7 / 4.1 / 5 mm

c) neck length

3 mm

d) length abutment

7.2 mm

e) neck Ø

2.0/2.5/2.8 mm

f) Ø abutment

3.9 mm

KOS® X implants are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

KOS® XB

KOS® XB IMPLANTS KOS® XB implants provide the same prosthetic platform (cementing head) as BCS implants with Ø 3.6 mm, 4.6 mm and > 5.5 mm, as well as BOI implants.

d f e

c

a

Description

enossal Ø

Length

Neck Ø

REF

Price cat.

KOS XB 3.0 15

3.0 mm

15 mm

1.9 mm

455750

F

KOS XB 3.2 12

3.2 mm

12 mm

1.9 mm

455760

F

KOS XB 3.2 15

3.2 mm

15 mm

1.9 mm

455761

F

KOS XB 3.7 12

3.7 mm

12 mm

1.9 mm

455770

F

a) enossal length

12 - 15 mm

b) enossal Ø

3.0 / 3.2 / 3.7 / 4.1 mm

c) neck length

3 mm

d) length abutment

7.2 mm

e) neck Ø

1.9 mm

f) Ø abutment

3.9 mm

KOS® XB implants are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

b

INSERTION TOOLS Description

Code

REF

Price cat.

For BCS implants with > Ø 5.5 mm KOS X, KOS XB, KOS Plus

IT2 BCS

900030

E

For BCS implants with > Ø 5.5 mm KOS X, KOS XB, KOS Plus

IT2 S BCS

900038

E

Length 23 mm, for KOS and BCS implants

IT2W

900039

C

Adapter for implants > Ø 5.5 mm, for handgrips REF 311430, 311431 / KOS X, KOS XB

AHB

900037

F

IMPRESSION TAKING AND LABORATORY ACCESSORIES Description

Unit

Material

Code

REF

Price cat.

Impression post Internally round

Pack of 5

plastic

TSPA 5*

462030

B

Impression and castable abutment

Pack of 5

PA X

462136

B

Double analogue

Pack of 5

plastic

IA4/IAU

462111

B

metal

IA4/IAU

462112

A

POB

462086

B

or Double analogue or Castable abutment

Pack of 5

*TSPA 4 & 5 For impressions on ground-down implant heads. This ring-transfer exposes the lower border of the abutment head. The impression is then poured with extra-strong gypsum or epoxi-resin. For this techniques no implant analogues are needed. Material: PP

25

26

KOS® MU

TEMPBASE® TEMPORARY BASE Description

Material

Code

REF

Price cat.

Temporary base, for large head

PEEK

TPB B

462026

C

Provisional base with internal and external grooves. Can be clipped directly onto the head of the KOS® implant and additionally secured with a little provisional cement if necessary. Polymerised directly into the long-term provisional bridge. Intended life 6 months.

KOS® MULTIUNIT IMPLANTS KOS® MU has a production-side fixed pre-angulation of 15 degrees. KOS® MU can also be bent using the insertion tool, which means that angulations relative to the endosseous implant axis of 0 to over 30 degrees are possible. In conjunction with the clinically possible rotational positions of the head, all possible angulations can thus conceivably be realised. Both implant types have the advantage of an enhanced screw thread that prevents the otherwise frequent screw fractures Description

Material

REF

Price cat.

KOS® MU 3.0 15

Ti6Al4V

455830

L

KOS® MU 3.7 15

Ti6Al4V

455831

L

KOS® MU 4.1 12

Ti6Al4V

455832

L

KOS® MU 4.1 15

Ti6Al4V

455833

L

KOS® MU 5.0 10

Ti6Al4V

455834

L

KOS® MU 5.0 12

Ti6Al4V

455835

L

Description

Code

REF

Price cat.

Insertion tool short. Total length 10,8 mm For RAT 2

IT1 MU15

418166

F

Insertion tool medium. Total length 23,8 mm Use with IT ITV (REF 500854)

IT2 MU15

418201

F

Insertion tool long. Total length 33,8 mm Use with IT ITV (REF 500854)

IT3 MU15

418202

F

Insertion tool for KOS MU & BCS MU Use with IT2 BCS, IT2 S BCS, AHB

ITX MU15

418203

F

Adapter For handgrip 311430 or 311431

Adapter IT MU 15

418167

D

Titanium base Use with SF K MU (REF 418164)

T-Base MU

418188

B

Castable abutment

PA2 MU

418189

B

Lab analogue for MU-implants

IA K MU

418159

A

Prosthetic screw for KOS® MU and BCS® MU

SF K MU

418164

B

Long screw for TC MU and TS MU (Tool: HT 1.25). Material Ti6Al4V

SFL MU

418168

B

UCLA castable abutment for MU-implants SF K MU must be ordered separately

PA MU

418119

B

Transfer Coping (Temporary base) SF K MU must be ordered separately

TC MU

418161

D

Transfer, straight SF K MU must be ordered separately

TS MU

418162

C

ACCESSORIES

KOS® K

KOS® K IMPLANTS Perfectly manufactured precision implant that is double-sandblasted on the endosseous part made of highly fracture-resistant titanium alloy Ti6Al4V. KOS® K implants with ball head are used for fixation of prostheses with nylon caps. f

d c

f

a

Description

Code KDS

Enossal Ø

Length

Neck Ø

REF

Price cat.

KOS K 3.0 12

B

3.0 mm

12 mm

2.0 mm

455152

KOS K 3.0 15

C

3.0 mm

15 mm

2.0 mm

455150

F

KOS K 3.7 12

F

3.7 mm

12 mm

2.8 mm

455154

F

F

KOS K 3.7 15

G

3.7 mm

15 mm

2.8 mm

455155

F

KOS K 4.1 15

L

4.1 mm

15 mm

2.8 mm

455156

F

Description

Code

REF

Price cat.

Cementable base for KOS® K, Material Ti6Al4V

CAK

462059

B

455180

B

a) enossal length

12-15 mm

b) enossal Ø

3.0 / 3.7 / 4.1 mm

c) length (non-blasted)

7 mm

d) length abutment

4 mm

e) hight of hexagon

2 mm

f) ballhead Ø

2.85 mm

b

IMPRESSION TAKING AND LABORATORY ACCESSORIES

Use with Lab analogue AAA (REF462049 Castable abutment PA AAA (REF462050) IAK lab analogue

REMOVING FORCE Nylon cap NC ca. 1200 g, white

NC

465028

A

ca. 800 g, pink

NC 1

465029

A

ca. 500 g, yellow

NC 2

465030

A

Nylon cap R-NC with increased friction strength (for usage with worn-out ball only) green, strong

NC 3

465034

A

pink, medium

R-NC

465033

A

orange, soft

R-NC 1

465032

A

Sleeve for all NC

R-NC 2

465031

B

PA SB

A

Castable ball for single-piece cast with bar connector

27

28

KOS®

INSERTION TOOL Description

REF

Price cat.

IT TB K

462327

D

Description

REF

Price cat.

Ball head adapter for KOS® K implants, cementable

462051

B

BALL HEAD ADAPTER (SPARE BALL)

KDS BONE EXPANDING SCREWS For all KOS® B screw implants, bone-expanding screws are available as tools to create the definitive implant cavity. Basically, for each implant prior to insertion of a KOS® B screw implant, a bone compression with the bone-expanding screw should be performed. In addition, with a narrow alveolar ridge, an expansion of the alveolar ridge can be performed with the bone-expanding screw. By inserting the bone-expanding screw, it can be checked whether the KOS® B screw implant can be inserted into the bone easily and fully. Titanium alloy Ti6Al4V Eli, non-blasted. Tighten with IT K, ITS K or ITX K using the torque ratchet TW2 (max. 45 Ncm), or alternatively RAT2. Package unit: 1 piece, non-sterile.

d c f

e

a

Description

Code KDS

Enossal Ø

Length

Neck Ø

REF

Price cat.

KDS 3.0 10

A

3.0 mm

10 mm

2.0 mm

455212

F

KDS 3.0 12

B

3.0 mm

12 mm

2.0 mm

455213

F

KDS 3.0 15

C

3.0 mm

15 mm

2.0 mm

455214

F

KDS 3.2 12

D

3.2 mm

12 mm

2.5 mm

455223

F

KDS 3.2 15

E

3.2 mm

15 mm

2.5 mm

455224

F

KDS 3.7 12

F

3.7 mm

12 mm

2.8 mm

455233

F

KDS 3.7 15

G

3.7 mm

15 mm

2.8 mm

455234

F

KDS 4.1 8

H

4.1 mm

8 mm

2.8 mm

455241

F

KDS 4.1 10

I

4.1 mm

10 mm

2.8 mm

455242

F

KDS 4.1 12

K

4.1 mm

12 mm

2.8 mm

455243

F

KDS 4.1 15

L

4.1 mm

15 mm

2.8 mm

455244

F

KDS 4.1 17

M

4.1 mm

17 mm

2.8 mm

455245

F

KDS 4.1 19

N

4.1 mm

19 mm

2.8 mm

455246

F

b a) enossal length

8 - 19 mm

b) enossal Ø

3.0 / 3.2 / 3.7 / 4.1 / 5 mm

c) length (non-blasted)

10 mm

d) length abutment

6.8 mm

The bone-expanding screws can easily be screwed in using suitable insertion tools and immediately screwed out again after reaching the full insertion depth. Subsequently, the KOS® B implant is inserted. With the KOS® B (bendable), the use of bone-expanding screws is mandatory regardless of the region, so that the shear forces occurring during insertion do not twist the implant neck.

e) neck Ø

2.0 mm

Do not use for KOS® implants with microthread.

f) neck length

3 mm

KOS®

INSERTION TOOLS Description

Type

Length

Code

REF

Price cat.

For KOS, KOS B, KDS

long

20 mm

IT K

462320

C

For KOS, KOS B, KDS

extra long

45 mm

ITX K

462321

C

For KOS, KOS B, KDS

short

7 mm

ITS K

462322

C

For KOS, KOS B, KDS

contra-angle / hex

23 mm

ITWH K *

462323

C

For KOS, KOS B, KDS

contra-angle

23 mm

ITW K

462331

C

For KOS K

long

20 mm

IT TB K

462327

D

For KOS B **

long

20 mm

Tool E **

462377

D

For KOS E

long

20 mm

IT TCA

425065

D

Hex

* Only for W+H contra-angles with new drive ** Emergency tool for KOS® and BCS®

INSTRUMENTS AND TOOLS Description

Length

Code

REF

Price cat.

DX 2

500704

D

PDG

425400

A

Radiol. measure pin Fits to DOS 1

CDG

420329

A

Ratchet for all hex instruments and insertion tools

RAT2

425051

K

Torque wrench 10-70 Ncm

TW2 *

425402

S

Drill extension extends by 19 mm

Standardized probe 1-mm scale for radiological measurements

22 mm

* It is recommended to have the torque ratchets recalibrated by us once a year.

29

KOS®

30

HANDGRIP DISMOUNTABLE

HANDGRIP NOT DISMOUNTABLE

Please note the cleaning instructions on p. 61-62 of this system application brochure.

Please note the cleaning instructions on p. 61-62 of this system application brochure.

Length

REF

Price cat.

Length

REF

Price cat.

110 mm

311430

V

110 mm

311431

V

DRILLS

ADAPTER

INSERTION TOOLS

Adapter for all contra-angle instruments, suitable for handgrip

For KOS®, KOS® B, KOS® T, KOS® KDS, BCS 3.5, BCS 4.5

For KOS® X KOS® XB, KOS® Plus, BCS 3.6, BCS 4.6, ab > 5.5

For KOS MU, BCS MU

100 mm

60 mm

70 mm

70 mm

60 mm

Description

Length

100mm

100 mm

Code

BCD 1 Adapter Twist Drill 2.0

Twist Drill 2.5

Adapter RA

Adapter AHK

Adapter AHB

Adapter IT MU 15

REF

310511

310512

310513

310530

462319

900037

418167

Price cat.

F

F

F

D

B

F

D

KOS®

HANDGRIP TRAY

Size of closed tray B 195 mm T 90 mm H 45 mm For all autoclaves

Description

Length

REF

BCD 1 Adapter

100 mm

310511

Twist Drill 2.0

100 mm

310512

Twist Drill 2.5

100 mm

310513

Adapter RA

60 mm

310530

Adapter AHK

70 mm

462319

Adapter AHB

70 mm

900037

Handgrip

110 mm

311430

Price €

Handgrip tray empty

60043

69,90

Handgrip tray with content

S60043

609,20

Description

REF

Price €

Replacement O-ring for handgrip 311430

311430-OR

2,20

ACCESSORIES

Please read our detailed instructions for cleaning and re-sterilisation of surgical instruments on www.implant.com/images/Instructions/GA/Implantate/996-Hygmblatt.pdf

31

KOS®

32

INSTRUMENT TRAY FOR KOS® & BCS®

Size of closed tray B 175 mm T 145 mm H 65 mm For all autoclaves. Autoclavable up to 134°C, not suitable for dry heat sterilizers.

Description

System

Head

REF

Description

System

REF

IT2 BCS

KOS/BCS

large

900030

Twist Drill 2.0 30

BCS

90020

IT2 S BCS

KOS/BCS

large

900038

Twist Drill 2.0 21

BCS

90022

IT2 W

KOS/BCS

large

900039

Twist Drill 2.5 21

BCS

90026

IT K

KOS/BCS

small

462320

BCD 1

KOS/BCS

900240

IT15 K

KOS/BCS

small

462325

BCD 2

KOS/BCS

900241

ITS K

KOS/BCS

small

462322

BCD 3

KOS/BCS

900242

ITS15 K

KOS/BCS

small

462328

BCDX 1

KOS/BCS

900243

ITW K

KOS/BCS

small

462331

BCDX 2

KOS/BCS

900244

ITWH K

KOS/BCS

small

462323

BCDX 3

KOS/BCS

900245

DOS 1

KOS

455311

CDG

KOS/BCS

420329

DOS 2

KOS

455312

CDG

KOS/BCS

420329

DOS 3

KOS

455313

DX 2

KOS/BCS

500704

DOS 4

KOS

455314

TW 2

KOS/BCS

425402

Price €

DOS 5

KOS

455315

C-Drill KM 1

KOS

455300

C-Drill KM 2

KOS

455301

C-Drill KM 3

KOS

455302

IT LOC K

KOS

462333

DS 2

KOS

425001

Instrument tray empty

60006-K

299,90

IT TB K

KOS

462327

Instrument tray with content

S60006-K

1.726,60

The content for the system BCS® is optional

KOS®

DRILLSTOPP TRAY Not suitable for dry heat sterilizers.

Depth Drills

Drills Drillstop

KOS 3.0 (3.2)

Depth Drills

Drillstop

KOS 4.1

10

DOS 1

K

8

DOS 3

L

12

DOS 1

H

10

DOS 3

K

15

DOS D 1

D

12

DOS 3

H

15

DOS 4

K

17

DOS 4

H

19

DOS 4

F

KOS 3.7 10

DOS 2

K

12

DOS 2

H

15

DOS 2

D

KOS 5.0 10

DOS 5 (6)

K

12

DOS 5 (6)

H

15

DOS 5 (6)

D

Description

REF

Price €

Drillstopp B

500882

Drillstopp C

500883

Drillstopp D

500884

Drillstopp F

500886

Drillstopp H

500888

Drillstopp K

500891

Drillstopp L

500892

Drill DOS 1

455311

Drill DOS 2

455312

Drill DOS 3

455313

Drill DOS 4

455314

Drill DOS 5

455315

Drill DOS 6

455316

Drillstopp tray empty

60033-K

119,90

Drillstopp tray with content

S60033-K

498,00

IT HAS BEEN SCIENTIFICALLY PROVEN Heatless® drills by Dr. Ihde Dental generate 55 % less heat than traditional bone drills from other manufacturers. This makes it possible to use higher rotational speeds: between 3,000 and 5,000 rpm are recommended with good external cooling and intermittent drill technique.

STARTER TRAY Autoclavable up to 134°C, not suitable for dry heat sterilizers. This surgical kit contains all drills and tools for first works with the system KOS®. Material: autoclavable plastic.

Description

REF

IT K

462320

ITS K

462322

ITW K

462331

IT LOC K

462333

C-Drill KM 1

455300

C-Drill KM 2

455301

C-Drill KM 3

455302

IT MU 15

418166

IT ITV

500854

IT 2 BCS

900030

IT 2 S BCS

900038

DOS 1

455311

DOS 2

455312

DOS 3

455313

BCDX 1

900243

Torque wrench TW2

425402

Price €

Starter tray empty

60041-K

119,90

Starter tray with content

S60041-K

919,90

33

KOS®

34

KOS® IMPLANTATIONS Minimally invasive immediate load implantology with KOS® implants 1. Insertion of 21 KOS® implants in three hours. 2. Maxilla restoration with new motorised screwing technology. 3. Minimally invasive approach for beginners. Authors Dr. Werner Mander, (IMF) Dr. Thomas Fabritius

Description

REF

Price cat.

DVD

6668

A

APPLICATION AREAS (INDICATIONS) KOS® • • • •

Anchorage of crowns, bridges and bars, with the presence of adequate bone supply in terms of bone quality, bone width and bone height. There are no findings for use with simultaneous augmentations. Anchorage of prostheses via bar and button anchorage systems. Individual tooth restorations (KOS® implants only!).

USE RESTRICTIONS FOR KOS® A AND KOS® B • • • • • • • • • • • •

These two implant types may only be used as support implants in the reduced-load area. The interlocking of at least three and possibly several implants and „corner stiffening are required. At least one KOS® implant must be involved in the construction. The prosthetic restoration must be securely fixed (with definitive cements). Not to be used for segmented bridges without the involvement of at least two KOS® screws. If in doubt, angulation adapters on KOS® screws are preferable to the KOS® B implant. Avoid combining with basal implants for elasticity reasons. Not to be used for additional abutments in combination with natural teeth. Not to be used under diagonal load (off-axis load) as well as in deep-bite cases in the maxillary and mandibular anterior region. Max. width of occlusal surface 5 mm. Not to be used as terminal abutments. Bendable up to 13 degrees.

NOTES ON THE CARE OF SURGICAL STEEL INSTRUMENTS Surgical steel instruments can quickly become damaged if inadequately or improperly cared for. Only the special solvents for cleaning surgical steel should be used; in case of doubt, consult Dr. Ihde Dental GmbH / AG. The following are not recommended: • Disinfectants/cleaners with a high chlorine content. • Disinfectants/cleaners with a high oxalic acid content. For instruments with colour coding, the following are not recommended: • Excessively high solvent concentrations, disinfectants/cleaners with the components mentioned above. • Excessive temperatures in machine cleaning and sterilisation. • Never autoclave at higher than 134°C, and do not use a hot air steriliser.

KOS® Mini

KOS® MINI IMPLANTS KOS Mini 1.8 10

KOS Mini 1.8 12

KOS Mini 1.8 15

5,4 mm

5,4 mm

5,4 mm

10 mm

12 mm

15 mm

Description

Enossal Ø

Enossal length

Hight above bone

Material

Max. insertion torque

KOS® Mini 1.8 10

1.8 mm

10 mm

5.4 mm

Ti6AL4V

25 Ncm

KOS® Mini 1.8 12

1.8 mm

12 mm

5.4 mm

Ti6AL4V

25 Ncm

KOS® Mini 1.8 15

1.8 mm

15 mm

5.4 mm

Ti6AL4V

25 Ncm

KOS® Mini 2.4 12

2.4 mm

12 mm

5.4 mm

Ti6AL4V

40 Ncm

KOS® Mini 2.4 15

2.4 mm

15 mm

5.4 mm

Ti6AL4V

40 Ncm

KOS® Mini 2.4 18

2.4 mm

18 mm

5.4 mm

Ti6AL4V

40 Ncm

KOS® Mini 2.8 12

2.8 mm

12 mm

5.4 mm

Ti6AL4V

60 Ncm

KOS® Mini 2.8 15

2.8 mm

15 mm

5.4 mm

Ti6AL4V

60 Ncm

KOS® Mini 2.8 18

2.8 mm

18 mm

5.4 mm

Ti6AL4V

60 Ncm

35

KOS® Mini

1. DRILLING AND DRILL DEPTH KOS® Mini implants are inserted into the bone with self-tapping and with bone compression. As a rule, an under-sized pilot hole is sufficient. Recommended drill-speed: min. 3.000 Rpm, with sufficient cooling and intermittent drilling technique. Note regarding hard bone: The torque must not exceed 45 Ncm during insertion. Should this be the case, the implant must be rotated out and the drilling depth extended to 2/3 of the implant length.

15 mm 12 mm 10 mm

GINGIVA

18 mm

18 mm

15 mm

15 mm

12 mm

12 mm

Drill for KOS® Mini 1.8, ø 1.3 mm

Drill for KOS® Mini 2.4, ø 1.9 mm

Drill for KOS® Mini 2.8, ø 2.3 mm

REF455318

REF455319

REF455320

GINGIVA

BONE

Drilling in hard bone: 1/2 of the enossal implant length

BONE

36

Drilling in soft bone: 1/3 of the enossal implant length

KOS® Mini

37

1

2

3

4

SAME PROCEDURE WITH REF462374 / REF462376!

2. TO REMOVE THE IMPLANT FROM THE PACKAGE

3. INSERTION AND PLACEMENT TW 2

IT K KOS® Mini (long, 20 mm) REF462374

IT H KOS® Mini for manual insertion REF462375

GINGIVA

BONE

IT K KOS® Mini (short, 12 mm) REF462376

38

KOS® Mini

KOS® MINI SET 1.8 10

KOS® MINI SET 2.4 12 REF

Price cat.

KOS® Mini 1.8 10 (pack of 4) Drill for KOS® Mini DS, ø 1.3 mm

455050

Q

Sleeve and O-ring (set of 4)

Price cat.

455056

Q

REF

Price cat.

Drill for KOS® Mini DS, ø 1.3 mm

455051

Q

REF

Price cat.

455057

Q

REF

Price cat.

455055

Q

KOS® MINI SET 2.8 15 REF

Price cat.

KOS® Mini 2.4 15 (pack of 4)

KOS® Mini 2.8 15 (pack of 4) 455054

Q

Sleeve and O-ring (set of 4)

Drill for KOS® Mini DS, ø 2.3 mm Sleeve and O-ring (set of 4)

KOS® MINI SET 1.8 15

KOS® MINI SET 2.4 18 REF

Price cat.

KOS® Mini 1.8 15 (pack of 4)

KOS® Mini 2.4 18 (pack of 4) 455052

Q

Sleeve and O-ring (set of 4)

Drill for KOS® Mini DS, ø 1.9 mm Sleeve and O-ring (set of 4)

KOS® MINI SET 2.8 18 REF

Price cat.

455058

Q

KOS® Mini 2.8 18 (pack of 4)

Sleeve and O-ring (set of 4)

Q

Sleeve and O-ring (set of 4)

KOS® MINI SET 2.4 15

Drill for KOS® Mini DS, ø 2.3 mm

455053

KOS® Mini 1.8 12 (pack of 4)

Sleeve and O-ring (set of 4)

Drill for KOS® Mini DS, ø 1.3 mm

Drill for KOS® Mini DS, ø 1.9 mm

KOS® MINI SET 1.8 12 REF

KOS® Mini 2.8 12 (pack of 4)

Drill for KOS® Mini DS, ø 1.9 mm

Price cat.

Sleeve and O-ring (set of 4)

KOS® MINI SET 2.8 12

Drill for KOS® Mini DS, ø 2.3 mm

REF KOS® Mini 2.4 12 (pack of 4)

KOS® Mini

ACCESSORIES Description

Working length

Code

REF

Price cat.

Insertion tool short, 12 mm

IT K KOS® Mini

462376

C

Insertion tool long, 20 mm

IT K KOS® Mini

462374

C

Insertion tool (2-piece) for manual insertion

IT H KOS® Mini

462375

D

Torque wrench, 10 - 70 Ncm

TW2

425402

S

Impression coping KOS® Mini Pack of 4

462117

A

Analogue KOS® Mini Pack of 4

462116

A

Sleeve KOS® Mini for polymerizing into the prosthesis, delivery with inserted O-ring

462113

B

O-ring for sleeve REF 462113 for replacement. Pack of 4

462114

B

Depth-measurement-probe for KOS® Mini

462115

A

Drill for KOS® Mini, ø 1.3 mm

15 mm

455318

C

Drill for KOS® Mini, ø 1.9 mm

18 mm

455319

C

Drill for KOS® Mini, ø 2.3 mm

18,4 mm

455320

C

39

KOS® Micro

KOS® MICRO IMPLANTS

Small head 3.3 mmd x 6.8 mmh, with square

Large head 3.9 mmd (max.) x 7.2 mmh, with three vertical grooves for the insertion procedure

Cylindrical neck, 3.5 mmh with No-Itis® surface. 2.0 mm Ø, sracture-proof up to 80 Ncm insertion torque, bendable up to 15°.

Minimum insertion depth

455914 KOS Micro 3.7 15

Nominal length

455954 KOS MicroD 3.7 15

Microthread area 2.5 mmh, with No-Itis®-surface

455906 KOS Micro 3.2 15

40

Single compression thread in diameters 3.0 - 3.2

Compression thread area with triple treatment: blasted / etched / No-Itis®

Compression double thread with aggressive tip, available in diameters 3.7-5.0

CORTICAL MILLING FOR KOS® MICRO Description

Code

REF

Price cat.

C-Drill KM1 3.0 - 3.2

Cortical milling

C-Drill KM1

455300

E

C-Drill KM2 3.7 - 4.1

Cortical milling

C-Drill KM2

455301

E

C-Drill KM3 5.0

Cortical milling

C-Drill KM3

455302

E

KOS® Micro

MATERIAL Ti6AL4V, also known as „Grade 5 , is the high-purity version of the conventional 6/4 Ti alloy, which is used for more than 50% of all metallic human implants. This material is the first choice for all applications which require high stability, corrosion resistance and mechanical strength. This is why today s most modern dental implant designs are made of this material. This titanium alloy is superior to the alternatively used pure titanium in terms of stability by more than 25%. Also regarding biocompatibility and the support of bone cell growth, this titanium alloy shows advantages compared to pure titanium.

FUNCTIONALITY The one-piece KOS® Micro dental implant is preferably used in immediate loading. Unlike other compression screws, the polished neck has a cylindrical shape. Thus, the cortical is sealed, good retention is achieved in the cortical and the bone is protected against infections. At the same time, the endosseous implant part compresses the cancellous bone areas.

NOTE The smooth microthread must be completely submerged below the bone level. The cylindrical neck must extend into the bone at least 1 mm deep. Therefore, the implant must be selected so that at least 1.5 mm more usable vertical bone is present than the nominal length of the implant. Example For KOS Micro 3.7 15, 17 mm of usable vertical bone must be present. If in doubt, a shorter implant should be selected so as to ensure a sufficient insertion depth.

DRILLING PROCEDURE The pilot hole is made with the drills of the KOS® system. Except in very dense mandibular bone, the pilot hole is usually sufficient with BCD1 or DOS1.

INSERTION The implant can be inserted most easily with the handgrip (REF 311430) and the adapter (REF 900 037). When using the ratchet RAT2, small or medium insertion tools are used. Max. torque is 80 Ncm.

THE IMPLANTS ARE SUPPLIED WITH TWO DIFFERENT HEAD SIZES • Diameters 3.0 mm and 3.2 mm are supplied with a small head; they also fit in small individual tooth gaps • Diameters 3.7 mm, 4.1 mm and 5.0 mm are supplied with a large head. This head permits easy and speedy prosthetic restoration.

All KOS® Micro implants have circular grooves on the abutment head with a radius that fits 1.5mmd titanium rods. In this way, several implants can be joined together in the mouth directly through syncrystallisation (intraoral welding) and splinted immediately. This means that no metal splint needs to be incorporated into the provisional. The head of the implant is large enough to connect two stacked titanium wires each of diameter 1.5 mm by intraoral welding.

Even after years, almost no crestal bone loss occurs with the KOS® Micro due to the macro designs.

41

42

KOS® Micro

KOS® MICRO IMPLANTS WITH SMALL HEAD KOS® Micro with small head for the anterior tooth region and tight gaps

g

d

Description

Enossal Ø

Length

Neck Ø

KOS Micro 3.0 10

3.0 mm

10 mm

2.0 mm

KOS Micro 3.0 12

3.0 mm

12 mm

2.0 mm

KOS Micro 3.2 12

3.2 mm

12 mm

2.0 mm

KOS Micro 3.2 15

3.2 mm

15 mm

2.0 mm

Drill *

REF

Price cat.

455900

F

DOS 1

455901

F

or

455905

F

455906

F

BCD 1

c Max. insertion torque for KOS® Micro implants is 80 Ncm. * In very hard bone, it may be additionally necessary to make a cylindrical hole with a twist Drill 2.5 mmd to a depth of 2.5 mm. a

b

a) enossal length

10 - 15 mm

b) max enossal Ø small head

3.2 mm

c) neck Ø

2.0 mm

d) hight of head

6.8 mm

Material

Ti6Al4V

KOS® Micro implants are delivered incl. lab-set consisting of REF 462111, 462029 and 462088

KOS® MICRO IMPLANTS WITH LARGE HEAD KOS® Micro with large head for all applications

d

c

a

b

Description

Enossal Ø

Length

Neck Ø

Drill *

REF

Price cat.

KOS Micro 3.7 6

3.7 mm

6 mm

2.0 mm

DOS 2 / BCD 2

455910

F

KOS Micro 3.7 8

3.7 mm

8 mm

2.0 mm

DOS 2 / BCD 2

455911

F

KOS Micro 3.7 10

3.7 mm

10 mm

2.0 mm

DOS 2 / BCD 2

455912

F

KOS Micro 3.7 12

3.7 mm

12 mm

2.0 mm

DOS 2 / BCD 2

455913

F

KOS Micro 3.7 15

3.7 mm

15 mm

2.0 mm

DOS 2 / BCD 2

455914

F

KOS Micro 4.1 8

4.1 mm

8 mm

2.0 mm

DOS 3 / BCD 3

455920

F

KOS Micro 4.1 10

4.1 mm

10 mm

2.0 mm

DOS 3 / BCD 3

455921

F

KOS Micro 4.1 12

4.1 mm

12 mm

2.0 mm

DOS 3 / BCD 3

455922

F

KOS Micro 4.1 15

4.1 mm

15 mm

2.0 mm

DOS 3 / BCD 3

455923

F

KOS Micro 5 10

5 mm

10 mm

2.0 mm

DOS 5

455925

F

KOS Micro 5 12

5 mm

12 mm

2.0 mm

DOS 5

455926

F

Max. insertion torque for KOS® Micro implants is 80 Ncm. * In very hard bone, it may be additionally necessary to make a cylindrical hole with a twist Drill 2.5 mmd to a depth of 2.5 mm.

a) enossal length

6 - 15 mm

b) max enossal Ø large head

3.9 mm

c) neck Ø

2.0 mm

d) hight of head

7.2 mm

Material

Ti6Al4V

KOS® Micro implants are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

KOS® Micro

KOS® MICRO D IMPLANTS WITH LARGE HEAD KOS® Micro with self-tapping double thread

Description

Enossal Ø

Length

Neck Ø

Drill *

REF

Price cat.

KOS MicroD 3.7 6

3.7 mm

6 mm

2.0 mm

DOS 2 / BCD 2

455950

G

KOS MicroD 3.7 8

3.7 mm

8 mm

2.0 mm

DOS 2 / BCD 2

455951

G

KOS MicroD 3.7 10

3.7 mm

10 mm

2.0 mm

DOS 2 / BCD 2

455952

G

KOS MicroD 3.7 12

3.7 mm

12 mm

2.0 mm

DOS 2 / BCD 2

455953

G

KOS MicroD 3.7 15

3.7 mm

15 mm

2.0 mm

DOS 2 / BCD 2

455954

G

KOS MicroD 4.1 8

4.1 mm

8 mm

2.0 mm

DOS 3 / BCD 3

455957

G

KOS MicroD 4.1 10

4.1 mm

10 mm

2.0 mm

DOS 3 / BCD 3

455958

G

KOS MicroD 4.1 12

4.1 mm

12 mm

2.0 mm

DOS 3 / BCD 3

455959

G

KOS MicroD 4.1 15

4.1 mm

15 mm

2.0 mm

DOS 3 / BCD 3

455960

G

KOS MicroD 5 10

5 mm

10 mm

2.0 mm

DOS 5

455963

G

KOS MicroD 5 12

5 mm

12 mm

2.0 mm

DOS 5

455964

G

g d

c

a

b

Max. insertion torque for KOS® Micro implants is 80 Ncm. * In very hard bone, it may be additionally necessary to make a cylindrical hole with a twist Drill 2.5 mmd to a depth of 2.5 mm.

a) enossal length

6 - 15 mm

b) max enossal Ø large head

3.9 mm

c) neck Ø

2.0 mm

d) hight of head

7.2 mm

Material

Ti6Al4V

KOS® Micro D implants are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

43

44

KOS® Micro

IMPRESSION TAKING AND LABORATORY ACCESSORIES Description

Unit

Material

Code

REF

Price cat.

Impression cap

Pack of 5

POM

TSPA 4

462029

B

Castable abutment

Pack of 5

PO4

462088

B

Double analogue

Pack of 5

IA4/IAU

462111

B

Impression- and castable

Pack of 5

PA X

462136

A

Pack of 5

POB

462086

B

for small head

plastic

for large head

abutment

Castable abutment

PO4/MA4 POB/MA5

Gipsum

TITANIUM CROWN BASE Description

Material

Code

REF

Price cat.

Titanium cap, radio opaque

Ti6Al4V, weldable

MA4

462090

B

Titanium cap, radio opaque

Ti6Al4V, weldable

MA5

462093

B

Description

Material

Systems

REF

Price cat.

Scankörper-4

Peek

KOS, BCS

462054

B

Scankörper-5

Peek

KOS, BCS

462055

B

SCAN BODY

KOS® Micro

HEATLESS® DRILLS DOS FOR IMPLANTS WITH CONICAL CORE

-55% heat

Surgical steel, colour-coded, depth-coded and autoclavable. The drill is marked with laser depth markings. Use between 3,000 and 5,000 rpm with good cooling and intermittent drill technique. Due to the extremely high cutting performance, you can work without pressure. Description

Colour

Max. working length

REF

Price cat.

DOS 1

yellow

17 mm

455311

D

DOS 2

black

17 mm

455312

D

DOS 3

red

17 mm

455313

D

DOS 4

blau

21 mm

455314

D

DOS 5

green

17 mm

455315

D

DOS 6

transparent

15 mm

455316

D

DOS 6 This drill is 2 mm shorter at the tip. It can therefore drill up to 2 mm deeper into hard bone than nominally indicated on the drill. Therefore, the conical bone cavity is only circularly extended in the crestal area without increasing the drilling depth.

INSTRUMENTS AND TOOLS Description

Length

Code

REF

Price cat.

Insertion tool short, for large head. Use with RAT2 and TW2.

7 mm

IT2 S BCS

900038

E

Insertion tool medium, for large head. Use with RAT2 and TW2.

19 mm

IT2 BCS

900030

E

Insertion tool for large head. Use with angle piece.

23 mm

IT2W

900039

C

Insertion tool long, for small head. Use with RAT2 and TW2.

20 mm

IT K

462320

C

Insertion tool short, for small head. Use with RAT2 and TW2.

7 mm

ITS K

462322

C

Insertion tool for small head. Use with angle piece.

23 mm

ITW K

462331

C

TW2

425402

S

Torque wrench 10 - 70 Ncm. It is recommended to have the torque ratchets recalibrated by us once a year. Adapter for large head, use with handgrip.

70 mm

AHB

900037

F

Adapter for small head, use with handgrip.

70 mm

AHK

462319

B

Handgrip. Can be disassembled and cleaned manually.

110 mm

311430

V

Handgrip. For machine processing in the ultrasonic bath.

110 mm

311431

V

45

46

BCS®

APPLICATIONS OF IMPLANT SYSTEM FOR ENDOSSEOUS DENTAL IMPLANTS

BCS® implants can be used immediately diately in extrac extraction sockets if the basal support is sufficient. The anti-rotation tability against unintentional ntentional u protection ensures immediate stability unscrewing before prosthetic loading. The fore the 3rd post-operative po perative day. BCS® implants are made of high-strength, prosthesis should be inserted before Al4V (ASTM F 13 biocompatible titanium alloy Ti6Al4V 136). At least three im implants must be interlocked together. BCS® plants. Their use is permitted ermitted only by authorised users. belong to the basal (strategic) implants. ne Anzugsmom e for Implant Vorgeschriebene, bzw. empfohlene Anzugsmomente Implants, Abutments and Befestigungsschrauben finden Sie auf unserer Homepage unter www.implant.com/de/instructions

BCS®

BCS® IMPLANTS WITH SMALL HEAD FIELD OF APPLICATION enossal dental implant. These implants are used for the following indications. • Support implants for cortical anchorages of bridges • Manufacturing of a three-point support in individual regions of the jaw, for the cortical anchorage of dental prostheses

d

c

e

Description

a

b

e

g

Drill *

REF

Price €

BCS 2.7 10

2.7

10

2.55

4.5

DOS1 and / or DOS2

900200

599,90

BCS 2.7 12

2.7

12

2.95

4.5

DOS1 and / or DOS2

900201

599,90

BCS 2.7 14

2.7

14

2.95

5.5

DOS1 and / or DOS2

900202

599,90

BCS 2.7 17

2.7

17

2.95

5.5

DOS1 and / or DOS2

900203

599,90

BCS 2.7 20

2.7

20

2.95

5.5

DOS1 and / or DOS2

900204

599,90

BCS 2.7 23

2.7

30

2.95

5.5

DOS1 and / or DOS2

900205

599,90

f b

g

a

USE LIMITATIONS BCS 2.7 must not be used as an individual tooth implant. If only BCS 2.7 must be used in very thin jaws, then at least 12 implants per jaw must be inserted in the cortical anchorage.

a) thread Ø

max. 2.7 mm

b) enossal length

10 - 23 mm

c) Abutment hight

6.8 mm

d) max. abutment Ø

3.35 mm

e) length of flexible zone

2.55 & 2.95 mm

f) max. crestal Ø of shaft

1.9 mm

g) length of thread

4.5 & 5.5 mm

Tool

for BCS® with small head

BCS 2.7 implants are supplied exclusively in units of ten implants.

47

48

BCS®

BCS® IMPLANTS WITH SMALL HEAD BCS® implants 3.5 mmd - 12 mmd FIELD OF APPLICATION enossal dental implant. For anchorage in the 1st, 2nd and if necessary 3rd cortical, for the cortical anchorage of dental prostheses. BCS® implants can be used in sockets for a given indication immediately after extraction and loaded immediately in many cases. Mechanically smoothed surface in all areas. The abutment head is identical to the head of KOS® implants and the TSD4 abutment. Self-tapping thread with endosseous with anti-rotation protection. Conditionally suitable for individual tooth prostheses.

BCS 3.5 17

d

c

Description

a

b

e

f

g

REF

Price cat.

BCS 3.5 10

3.5

10

3

2.0

5.5

900208

G

BCS 3.5 12

3.5

12

5

2.0

5.5

900226

G

BCS 3.5 14

3.5

14

5

2.0

7.5

900210

G

BCS 3.5 17

3.5

17

8

2.0

7.5

900211

G

BCS 3.5 20

3.5

20

11

2.0

7.5

900212

G

BCS 3.5 23

3.5

23

14

2.0

7.5

900213

G

BCS 3.5 26

3.5

26

17

2.0

7.5

900214

G

BCS 3.5 29

3.5

29

20

2.0

7.5

900215

G

BCS 3.5 32

3.5

32

23

2.0

7.5

900216

G

BCS 3.5 35

3.5

35

26

2.0

7.5

900217

G

BCS 3.5 38

3.5

38

29

2.0

7.5

900218

G

BCS 4.5 14

4.5

14

5

2.3

7.5

900220

G

BCS 4.5 17

4.5

17

8

2.3

7.5

900221

G

BCS 4.5 20

4.5

20

11

2.3

7.5

900222

G

BCS 4.5 23

4.5

23

14

2.3

7.5

900223

G

BCS 4.5 26

4.5

26

17

2.3

7.5

900224

G

BCS 4.5 29

4.5

29

20

2.3

7.5

900225

G

f e b g

a

Insertion tools: IT KOS, ITX KOS, ITS KOS, Adapter AHK

a) thread Ø

3.5-4.5 mm

b) enossal length

10-38 mm

c) length abutment

6.8 mm

d) max. abutment Ø

3.35 mm

e) length of polished shaft

3-29 mm

f) max. crestal Ø of shaft

2-2.3 mm

g) length of thread

5.5-7.5 mm

Square key width

1.9 mm

BCS® implants are delivered incl. lab-set consisting of REF 462111, 462029 and 462088

Max. insertion torque 80 Ncm

BCS®

BCS® IMPLANTS WITH LARGE HEAD

BCS 3.6 17

d

c

f e b

g

a

BCS 4.6 14 BCS 5.5 14

Description

a

b

e

f

g

REF

Price cat.

BCS 3.6 10

3.6

10

4

2.0

5.5

900285

H

BCS 3.6 12

3.6

12

6

2.0

5.5

900284

H

BCS 3.6 14

3.6

14

5

2.0

7.5

900286

H

BCS 3.6 17

3.6

17

8

2.0

7.5

900287

H

BCS 3.6 20

3.6

20

11

2.0

7.5

900288

H

BCS 3.6 23

3.6

23

14

2.0

7.5

900289

H

BCS 3.6 26

3.6

26

17

2.0

7.5

900290

H

BCS 3.6 29

3.6

29

20

2.0

7.5

900291

H

BCS 4.6 8

4.6

8

3

2.1

5.5

900299

H

BCS 4.6 10

4.6

10

4

2.1

5.5

900292

H

BCS 4.6 12

4.6

12

6

2.1

5.5

900300

H

BCS 4.6 14

4.6

14

5

2.1

7.5

900293

H

BCS 4.6 17

4.6

17

8

2.1

7.5

900294

H

BCS 4.6 20

4.6

20

11

2.1

7.5

900295

H

BCS 4.6 23

4.6

23

14

2.1

7.5

900296

H

BCS 4.6 26

4.6

26

17

2.1

7.5

900297

H

BCS 4.6 29

4.6

29

20

2.1

7.5

900298

H

BCS 5.5 8

5.5

8

3

2.1

5.5

900255

K

BCS 5.5 10

5.5

10

4.5

2.1

5.5

900281

K

BCS 5.5 12

5.5

12

4.5

2.1

6.0

900250

K

BCS 5.5 14

5.5

14

6.5

2.1

6.0

900251

K

BCS 5.5 17

5.5

17

9.5

2.1

6.0

900252

K

BCS 5.5 20

5.5

20

12.5

2.1

6.0

900253

K

BCS 5.5 23

5.5

23

15.5

2.1

6.0

900265

K

BCS 5.5 26

5.5

26

18.5

2.1

6.0

900266

K

BCS 5.5 29

5.5

29

21.5

2.1

6.0

900267

K

Insertion tools: IT2 BCS, IT2 S BCS, Adapter AHB

a) thread Ø

3.6-4.6 mm

b) enossal length

10-29 mm

c) length abutment

7.2 mm

d) abutment Ø

3.9 mm

e) length of polished shaft

3-20 mm

f) max. crestal Ø of shaft

2.0-2.3 mm

g) length of thread

5.5-7.5 mm

BCS® Implants with large head are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

Max. insertion torque 80 Ncm

49

BCS®

50

BCS® IMPLANTS WITH LARGE HEAD Description BCS 12 12

d

c

f e b

g

a

BCS 7 12 BCS 9 14 BCS 10.5 14

a

b

e

f

g

REF

Price cat.

BCS 7 8

7

8

3

2.1

5.5

900258

K

BCS 7 10

7

10

4.5

2.1

5.5

900282

K

BCS 7 12

7

12

5

2.1

5.5

900260

K

BCS 7 14

7

14

7

2.1

5.5

900261

K

BCS 7 17

7

17

10

2.1

5.5

900262

K

BCS 7 20

7

20

13

2.1

5.5

900263

K

BCS 9 8

9

8

2.4

2.3

5.5

900269

M

BCS 9 10

9

10

2.8

2.3

5.5

900270

M

BCS 9 12

9

12

4.8

2.3

5.5

900274

M

BCS 9 14

9

14

6.8

2.3

5.5

900271

M

BCS 10.5 10

10.5

10

2.8

2.3

6.5

900276

M

BCS 10.5 12

10.5

12

4

2.3

6.5

900277

M

BCS 10.5 14

10.5

14

6

2.3

6.5

900278

M

BCS 10.5 17

10.5

17

9

2.3

6.5

900280

M

BCS 12 8

12

8

2.5

2.3

5.5

900279

O

BCS 12 10

12

10

2.7

2.3

5.5

900272

O

BCS 12 12

12

12

4

2.3

6.5

900275

O

BCS 12 14

12

14

6

2.3

6.5

900273

O

Insertion tools: IT2 BCS, IT2 S BCS, Adapter AHB

a) thread Ø

5.5-12 mm

b) enossal length

10-20 mm

c) length abutment

7.2 mm

d) abutment Ø

3.9 mm

e) length of polished shaft

3-13 mm

f) max. crestal Ø of shaft

2.3-2.4 mm

g) length of thread

5.5-6.5 mm

BCS® Implants with large head are delivered incl. lab-set consisting of REF 462111, 462136 and 462086

Max. insertion torque 80 Ncm

USE OF THE HANDGRIP IN THE EXAMPLE OF A LARGE HEAD BCS® IMPLANT

1.0

Use of the handgrip

1.1

Break off and implant immediately in the designated place

AHB

Handgrip

BCS®

ACCESSORIES FOR BCS® 3.5 TO 12 BCS® with the sizes 3.5 / 4.5 are compatibel with the following analogues and impression posts of the KOS® systems:.

Description

Amount

Code

REF

Price cat.

Impression post castable Internally round For small head

Pack of 5

TSPA 4

462029

B

Impression post (plastic) Internally round For large head

Pack of 5

TSPA 5

462030

B

IA4/IAU

462112

A

Double analogue (metal)

or

Double analogue (plastic)

Pack of 5

IA4/IAU

462111

B

Castable abutment 7 mm high, white Internally round For small head

Pack of 5

PO4

462088

B

Castable abutment For large head

Pack of 5

POB

462086

B

51

52

BCS®

BCS® MULTIUNIT IMPLANTS FIELD OF APPLICATION enossal dental implant. BCS® MU has a production-side fixed pre-angulation of 15 degrees. BCS® MU can also be bent after insertion using the insertion tool, whereby angulations relative to the endosseous implant axis of 0 to over 30 degrees are possible. Since the implant head itself can be positioned in any direction, directional changes for the prosthetic screw of between -15 and +15 degrees are possible due to the preangulation. In addition, if the neck is bent by max. 15 degrees, angulations of the prosthetic screw of between -30 and +30 degrees over the implant axis can be achieved. BCS® MU implants may be used by authorised users only. Material Ti6Al4V. Description

REF

Price cat.

Description

REF

Price cat.

BCS® MU 3.6 8

900397

N

BCS® MU 3.6 26 900377

N

BCS® MU 3.6 10 900398

N

BCS® MU 3.6 29 900378

N

BCS® MU 3.6 12 900376

N

BCS® MU 5.5 10 900334

N

BCS® MU 3.6 14 900330

N

BCS® MU 5.5 12 900335

N

BCS® MU 3.6 17 900331

N

BCS® MU 5.5 14 900336

N

BCS® MU 3.6 20 900332

N

BCS® MU 7.0 10

900337

N

BCS® MU 3.6 23 900333

N

BCS® MU 7.0 12

900338

N

Description

Code

REF

Price cat.

Insertion tool short. Total length 10,8 mm For RAT 2

IT1 MU 15

418166

F

Insertion tool medium. Total length 23,8 mm Use with IT ITV (REF 500854)

IT2 MU15

418201

F

Insertion tool long. Total length 33,8 mm Use with IT ITV (REF 500854)

IT3 MU15

418202

F

Insertion tool for KOS MU & BCS MU Use with IT2 BCS, IT2 S BCS, AHB

ITX MU15

418203

F

Adapter For handgrip 311430 or 311431

Adapter IT MU 15

418167

D

Titanium base Use with SF K MU (REF 418164)

T-Base MU

418188

B

Castable abutment

PA2 MU

418189

B

Lab analogue for MU-implants

IA K MU

418159

A

Prosthetic screw for KOS® MU and BCS® MU

SF K MU

418164

B

Long screw for TC MU and TS MU (Tool: HT 1.25). Material Ti6Al4V

SFL MU

418168

B

UCLA castable abutment for MU-implants SF K MU must be ordered separately

PA MU

418119

B

Transfer Coping (Temporary base) SF K MU must be ordered separately

TC MU

418161

D

Transfer, straight SF K MU must be ordered separately

TS MU

418162

C

ACCESSORIES

BCS®

PATHFINDER DRILLS Conical 3-edge drill as initial drill, ideally suited for all crestal implant systems. The drill also passes between narrow cortical areas without pressure.

I I

I

39 mm

47 mm

15 mm

I

Description

Colour

Max. working length

REF

Price cat.

BCD 1

yellow

15 mm

900240

C

BCD 2

black

15 mm

900241

C

BCD 3

red

15 mm

900242

C

BCDX 1

yellow

15 mm

900243

C

BCDX 2

black

15 mm

900244

C

BCDX 3

red

15 mm

900245

C

310511

F

I

I BCD 1 Adapter pathfinder for handgrip length 100 mm

TWIST DRILLS Description

Ø

Max. working length

REF

Price cat.

Twist Drill 2.0/21

2.0 mm

21 mm

90022

D

Twist Drill 2.0/30

2.0 mm

30 mm

90020

D

Twist Drill 2.0/40

2.0 mm

40 mm

90019

D

Twist Drill 2.5/21

2.5 mm

21 mm

90026

D

Description

Length

REF

Price cat.

Twist Drill 2.0 cylindrical drill 2.0 mm for handgrip

100 mm

310512

F

Twist Drill 2.5 cylindrical drill 2.5 mm for handgrip

100 mm

310513

F

310515

F

310516

F

Pilot drill for surgical handgrip Twist Drill 2.0/30 for surgical handgrip

110 mm

53

54

BCS®

INSERTION TOOLS AND ADAPTER Description

Code

REF

Price cat.

For BCS® implants with Ø 3.5 mm + 4.5 mm

IT K

462320

C

For BCS® implants with Ø 3.6, 4.6, 5.5, 7, 9, 10.5, 12 mm

IT2 BCS

900030

E

For BCS® implants with Ø 3.6, 4.6, 5.5, 7, 9, 10.5, 12 mm

IT2 S BCS

900038

E

For BCS® implants with Ø 3.6, 4.6, 5.5, 7, 9, 10.5, 12 mm. For handgrip REF 311430 & 311431

AHB

900037

F

310530

D

462319

B

Adapter for contra-angle instruments For handgrip REF 311430 & 311431

Adapter zu BCS 3.5/4.5 & KOS® For handgrip REF 311430 & 311431

AHK

WIRES FOR INTRAORAL WELDING

Description

Material

Ø

REF

Price cat.

Titanium wire (5 pieces á 15cm / pack)

TiGr.2

1.5 mm

462001

B

Titanium wire (5 pieces á 15cm / pack)

TiGr.2

2.0 mm

462002

B

Titanium wire (5 pieces á 15cm / pack)

Ti6Al4V

2.0 mm

462003

B

BCS®

Provisional

Provisional

Nanda S., Ihde S., Nanda P. Intra-oral welding-A usefull adjunct in immediate loading implantology using BCS implants. CMF Impl. Dir. Vol 9, No.2, 13-24, 2014

TITANIUM CAPS AND BAR PROFILES

NEW

Multi-use titanium caps for: • use in immediately lasered bridge frames, together with the bar profiles (without bar matrices) • the radiological control of plastic modelling • for direct polymerisation into the bridge prosthesis • direct veneering with titanium ceramic • material: Ti Grade 4

FOR WELDING

Description

Code

REF

Price cat.

Titanium cap, radio opaque for KOS, KOS B, BCS 3.5, BCS 4.5

MA4

462090

B

Titanium cap, radio opaque for KOS X, KOS Plus, BCS 3.6, BCS 4.6-BCS 12

MA5

462093

B

Bar sleeve, titanium, large; 3.0 mm high, 2.2 mm wide, 55 mm long

SP1

B

Bar sleeve, titanium, small; 2.3 mm high, 1.6 mm wide, 55 mm long

SP2

B

Titanium bar matrix for SP 1, length 55 mm

SP6

G

Titanium bar matrix for SP 2, length 55 mm

SP7

G

SCAN BODY Description

Material

Systems

REF

Price cat.

Scankörper-4

Peek

KOS, BCS

462054

B

Scankörper-5

Peek

KOS, BCS

462055

B

55

56

BCS®

CEMENTABLE ANGULATION ADAPTER (TI6AL4V) These adapters are mounted on BCS® implants to compensate for the insertion direction. Plastic cements are preferably used. The implant head must be roughened beforehand. The protruding head parts are then removed. The impression is taken directly on the adapter. Description

Hight

Code

REF

Price cat.

Adapter, 15°

7.5

AA15 KK

462036

C

Adapter, 25°

7.8

AA25 KK

462046

C

Adapter short, for large head

AA5 15°

462052

C

Adapter short, for large head

AA5 25°

462053

C

AA15 KK AA25 KK

AA5 15° AA5 25°

CASTABLE CROWN BASE These adapters are used by the dental technician for modelling of bridge frames. In the metal try-in, the protruding head parts are removed by the dentist.

Description

Hight

Code

REF

Price cat.

Adapter, pack of 5, reducible

7.5

AAL 15 KK

462045

E

LAB ANALOGUE Description

Code

REF

Price cat.

Abutment analogue for angulation adapter 15°and 25°

AAA

462049

B

Description

Code

REF

Price cat.

Castable abutment and transfer for AAA (pack of 5)

PA AAA

462050

A

CASTABLE ABUTMENT AND IMPRESSION TRANSFER

CEMENTING ABUTMENT Replacement abutment for cementing. For BCS implants up to a shaft diameter of 2.1 mm. Larger shafts must be ground down. Allows the vertical correction of the abutment position. Mounting e.g. with Fuji Plus. With drain hole, machined surface. Material Ti6Al4V.

B21

B21 ANA

Description

Code

REF

Price cat.

Replacement abutment for BCS, internal diameter 2.15 mm

B21

900316

A

Replacement abutment for BCS, anatomically shaped, can be ground down, height above gingiva 7.55 mm, transgingival height 1.5 mm

B21 ANA

462021

C

BCS®

HANDGRIP DISMOUNTABLE

HANDGRIP NOT DISMOUNTABLE

Please note the cleaning instructions on p. 61-62 of this system application brochure.

Please note the cleaning instructions on p. 61-62 of this system application brochure.

Length

REF

Price cat.

Length

REF

Price cat.

110 mm

311430

V

110 mm

311431

V

DRILLS

ADAPTER

INSERTION TOOLS

Adapter for all contra-angle instruments, suitable for handgrip

For KOS®, KOS® B, KOS® T, KOS® KDS, BCS 3.5, BCS 4.5

For KOS® X KOS® XB, KOS® Plus, BCS 3.6, BCS 4.6, ab > 5.5

For KOS MU, BCS MU

100 mm

60 mm

70 mm

70 mm

60 mm

Description

Length

100mm

100 mm

Code

BCD 1 Adapter Twist Drill 2.0

Twist Drill 2.5

Adapter RA

Adapter AHK

Adapter AHB

Adapter IT MU 15

REF

310511

310512

310513

310530

462319

900037

418167

Price cat.

F

F

F

D

B

F

D

57

58

BCS®

HANDGRIP TRAY

Size of closed tray B 195 mm T 90 mm H 45 mm For all autoclaves

Description

Length

REF

BCD 1 Adapter

100 mm

310511

Twist Drill 2.0

100 mm

310512

Twist Drill 2.5

100 mm

310513

Adapter RA

60 mm

310530

Adapter AHK

70 mm

462319

Adapter AHB

70 mm

900037

Handgrip

110 mm

311430

Price €

Handgrip tray empty

60043

69,90

Handgrip tray with content

S60043

609,20

Description

REF

Price €

Replacement O-ring for handgrip 311430

311430-OR

2,20

ACCESSORIES

Please read our detailed instructions for cleaning and re-sterilisation of surgical instruments on www.implant.com/images/Instructions/GA/Implantate/996-Hygmblatt.pdf

BCS®

INSTRUMENT TRAY FOR KOS® & BCS®

Size of closed tray B 175 mm T 145 mm H 65 mm For all autoclaves. Autoclavable up to 134°C, not suitable for dry heat sterilizers.

Description

System

Head

REF

Description

System

REF

IT2 BCS

KOS/BCS

large

900030

Twist Drill 2.0 30

BCS

90020

IT2 S BCS

KOS/BCS

large

900038

Twist Drill 2.0 21

BCS

90022

IT2 W

KOS/BCS

large

900039

Twist Drill 2.5 21

BCS

90026

IT K

KOS/BCS

small

462320

BCD 1

KOS/BCS

900240

IT15 K

KOS/BCS

small

462325

BCD 2

KOS/BCS

900241

ITS K

KOS/BCS

small

462322

BCD 3

KOS/BCS

900242

ITS15 K

KOS/BCS

small

462328

BCDX 1

KOS/BCS

900243

Price €

ITW K

KOS/BCS

small

462331

BCDX 2

KOS/BCS

900244

ITWH K

KOS/BCS

small

462323

BCDX 3

KOS/BCS

900245

DOS 1

KOS

455311

CDG

KOS/BCS

420329

DOS 2

KOS

455312

CDG

KOS/BCS

420329

DOS 3

KOS

455313

DX 2

KOS/BCS

500704

DOS 4

KOS

455314

TW 2

KOS/BCS

425402

DOS 5

KOS

455315

C-Drill KM 1

KOS

455300

C-Drill KM 2

KOS

455301

C-Drill KM 3

KOS

455302

IT LOC K

KOS

462333

DS 2

KOS

425001

Instrument tray empty

60006-K

299,90

IT TB K

KOS

462327

Instrument tray with content

S60006-K

1.726,60

The content for the system KOS® is optional

59

60

BCS®

INSERTION TOOLS Description

Type

Length

For implant

REF

Price cat.

IT K

long

20 mm

BCS, KOS, KOS B, KDS

462320

C

ITX K

extra long

45 mm

BCS, KOS, KOS B, KDS

462321

C

ITS K

short

7 mm

BCS, KOS, KOS B, KDS

462322

C

IT2 BCS

long

20 mm

BCS, KOS, KOS B, KDS

900030

H

IT2 S BCS

short

7 mm

BCS, KOS X, KOS Plus

900038

D

23 mm

KOS, BCS

900039

C

IT2W

Tool E Emergency tool for KOS® and BCS®

long

20 mm

BCS, KOS B

462377

D

IT TCA

long

20 mm

BCS, KOS E

425065

D

Description

REF

Price €

IT K

462320

ITS K

462322

IT 2 BCS

900030

IT 2 S BCS

900038

BCD1

900240

Twist Drill 2.0 21

90022

Twist Drill 2.0 30

90020

Twist Drill 2.5 21

90026

BCDX 1

900243

IT2 MU 15

418166

IT ITV

500854

Torque wrench TW2

425402

STARTER TRAY Autoclavable up to 134°C, not suitable for dry heat sterilizers. This surgical kit contains all drills and tools for first works with the system BCS®. Material: autoclavable plastic.

Starter tray empty

60040-K

119,90

Starter tray with content

S60040-K

708,80

BCS®

61

Basal implants may only be used and operated by qualified persons with valid authorisation (para. 2 MedProdAnw Ordinance). We are certified according to DIN EN ISO 13485 and Annex II of Directive 93/42 EEC. The product dimensions shown in this brochure may differ from reality for technical reasons. KOS® and BCS® are registered trademarks. Pat. Pend. If implants are reprocessed, there is a risk of the development of infections, because no validated method for processing exists. Implants therefore may not be reprocessed.

Compilation and explanation of possible symbols on the packaging:

Rx ONLY Production No.

Sterilized by gamma radiation

Sterilization Ethylene oxide

Nonsterile

Intended for use by dentists or surgeons only

Single use product

Instruction for use

Store tightly keep closed

Do not use if packing is damaged

Do not resterilize

Manufacturer

Production date

25°C -5°C Store in a dry place

Temperature range from -5°C to 25°C

Expiry date

KOS®

KOS® MU

KOS® PLUS

BCS®

BCS® MU

1st cortical

2nd cortical Application in healed bone areals

Dr. Ihde Dental AG Dorfplatz 11 CH - 8737 Gommiswald / SG Tel +41 (0)55 293 23 23 Fax +41 (0)55 293 23 00 [email protected] www.implant.com

Dr. Ihde Dental GmbH Erfurter Str. 19 D - 85386 Eching / Munich Tel +49 (0)89 319 761 0 Fax +49 (0)89 319 761 33 [email protected] www.ihde-dental.de

Application in fresh extraction sockets

REF 6641_KOS-BCS_EN_03/16_V031

Smile Life

When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile

Get in touch

© Copyright 2015 - 2024 PDFFOX.COM - All rights reserved.