Lean Solution for intelligent motor control center [PDF]

Lean Solution for intelligent. Motor Control Center www.eaton.eu. MCC. Motor Control Center. High system availability th

7 downloads 3 Views 1MB Size

Recommend Stories


Motor Control Center Solutions
The greatest of richness is the richness of the soul. Prophet Muhammad (Peace be upon him)

Freedom FlashGard motor control center
Don't watch the clock, do what it does. Keep Going. Sam Levenson

Freedom FlashGard Motor Control Center
Be like the sun for grace and mercy. Be like the night to cover others' faults. Be like running water

Vintage motor control center solutions
We must be willing to let go of the life we have planned, so as to have the life that is waiting for

[PDF] Download Motor Control
The best time to plant a tree was 20 years ago. The second best time is now. Chinese Proverb

Guidelines for intelligent lighting control
Nothing in nature is unbeautiful. Alfred, Lord Tennyson

Regenerative Intelligent Brake Control for Electric Motorcycles
Live as if you were to die tomorrow. Learn as if you were to live forever. Mahatma Gandhi

Adaptability of innate motor patterns and motor control mechanisms [PDF]
reflex, each associated with a certain functional goal, specific body positions, and motor-equivalent movement patterns. ...... neuron reflex arcs. Journal of Neurophysiology 9:439-44. [TRN]. Loeb, G. E. (1984) The control and responses of mammalian

Freedom 2100 motor control center installation and maintenance manual
Why complain about yesterday, when you can make a better tomorrow by making the most of today? Anon

quality control in lean construction
Don't count the days, make the days count. Muhammad Ali

Idea Transcript


MCC Motor Control Center

www.eaton.eu

Data

Fieldbus PLC

HMI/PLC

Energy

Lean Solution for intelligent Motor Control Center High system availability thanks to more data transparency The requirements placed on the communication functions of plants are constantly increasing. More and more information needs to be recorded and processed in order toachieve a high level of reliability and availability with reduced wiring costs. Using the concept of the SmartWire-DT communication system in the motor control center

(MCC) it is now possible to record information from the MCC drawer units simply and inexpensively and transfer this to the higher-level PLC. Thanks to the use of intelligent SmartWire-DT switchgear, this not only consists of digital signals for switching or monitoring of positions or overload information. Analog values such as the actual current or

the condition of a trip unit can be determined and evaluated. The data is transferred via standard fieldbus protocols to the controller. This firstly requires possible faults to be detected in advance in order to make timely interventions and eliminate the control wiring of the switchgear in the drawer unit.

Flexible in communication and time-saving in assembly For data exchange with the PLC there are a variety of Gateways available. This approach provide a high level of flexibility for communication with the controller. Features • Connection of up to 99 SWD slaves (with up to 1000 bytes of data) • Automatic addressing of the slaves on module exchange • Simple testing of the module without PLC with SWD Assist software • Simple expandability

High availability with intelligent switchgear The comprehensive data supplied by the PKE motor protection switch via SmartWire-DT enables energy consumption to be optimized and diagnostics to be carried out effectively so that faults can be rectified faster. The drawer units thus transfer essential detailed information to the higher-level controller so that operators can significantly increase the reliability and availability of their motors. Features High availability through overload prewarning functions • Extended diagnostics (short-circuit, overload, phase loss) • Actual motor current • Status of the overload release (thermal motor image) •

Simple mounting with SWD-Link The SWD-Link consisting of power supply module and cable adapter is the electrical and mechanical interface between the cable connection compartment and the MCC drawer unit. The benefit of this solution is the fact that this interface is identical for all MCC drawer units which can be tested in advance and thus reduce a time and cost intensive troubleshooting in the field. Furthermore the SmartWire-DT solution allows exchanging the drawer in operation without any effect on the communication. 1. SWD4-FFR-PF1-1 power supply module Connection to the central SmartWire-DT network between gateway and the drawer units • SmartWire-DT gateway to the drawer unit • Power supply •

2. SWD4-FFR-ST1-1 cable adapter Connection to central SmartWire-DT network via plug-in connection • Connection to the local SmartWire-DT network inside the drawer unit •

Ordering data

• •

power supply module cable adapter

© 2013 by Eaton Industries GmbH Subject to change without notice FL120002EN Artikelnr.: 171883

SWD4-FFR-PF1-1 SWD4-FFR-ST1-1

Art. 168880 Art. 168881

Smile Life

When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile

Get in touch

© Copyright 2015 - 2024 PDFFOX.COM - All rights reserved.