MR Perfusion Imaging - IHE Wiki [PDF]

Dec 16, 2013 - Create an Enhanced CT or MR SOP Instance: 2. Modality provides Dimension indices: Stack ID, In Stack Posi

6 downloads 16 Views 149KB Size

Recommend Stories


PET Myocardial Perfusion Imaging
Courage doesn't always roar. Sometimes courage is the quiet voice at the end of the day saying, "I will

MR imaging in
Don't watch the clock, do what it does. Keep Going. Sam Levenson

MR imaging study of
Ask yourself: If at the end of the year, you had accomplished one thing, what is the one accomplishment

Fetal MR imaging
So many books, so little time. Frank Zappa

ihe)
Learn to light a candle in the darkest moments of someone’s life. Be the light that helps others see; i

Wiki Guide PDF
We can't help everyone, but everyone can help someone. Ronald Reagan

MR Imaging of Pineal Tumors
Don’t grieve. Anything you lose comes round in another form. Rumi

MR Imaging of Epidermoid Cysts
Be who you needed when you were younger. Anonymous

hot topics in mr imaging
Almost everything will work again if you unplug it for a few minutes, including you. Anne Lamott

myocardial perfusion imaging or stress echocardiography?
The beauty of a living thing is not the atoms that go into it, but the way those atoms are put together.

Idea Transcript


CT/MR Perfusion Imaging From IHE Wiki CT/MR Perfusion with Contrast (PERF) facilitates the exchange and display of contrast perfusion CT or MR images.

Contents 1 Summary 2 Benefits 3 Details 4 Systems Affected 5 Specification 6 See Also

Summary The Profile uses the DICOM Enhanced CT and Enhanced MR objects to encode contrast perfusion images. Images are organized into stacks at different timeslots and indexed by their spatial position and time point. By requiring the use of standard attributes (instead of variable private tags) Image Displays can reliably display perfusion imaging correctly and conveniently.

Benefits Improves display View uptake of a contrast agent over time by using stacks of images at different timeslots. Defines how the perfusion images are stored and archived into frames of one Enhanced DICOM (Multi-frame) object so that they can later be retrieved and displayed in an unambiguous way on image viewers supporting Enhanced DICOM objects Improves the Consistency and Interoperability of the Perfusion Display with Contrast, clinical applications Provides standard attributes for “timing” and “position” information for the Workstation being capable of Display consistently and Interoperable Reduce implementations diversity of choices for improving interoperability Enables widespread and adequate review and interpretation of contrast-enhanced frames by radiologists in an IT environment where all Actors support the Enhanced CT or Enhanced MR DICOM objects Improves the acceptance of the Enhanced SOP Classes by industry and users Reduces Deployment Cost/Time

Details The CT/MR Perfusion Imaging with Contrast (PERF) Integration Profile: Facilitates the exchange of contrast enhanced images containing standard attributes for timing and position Defines how the perfusion images are stored and archived into frames of one Enhanced DICOM (Multi-frame) object so that they can later be retrieved and displayed in an unambiguous way on image viewers supporting Enhanced DICOM objects. The images need to be stored with indices along their position in the stack and the progress of time. A stack of images is being created at different timeslots, in order to display the contrast agent over time Defines the correct and convenient display of the Perfusion with Contrast Requirements for the Perfusion Creator modality are: 1. Create an Enhanced CT or MR SOP Instance 2. Modality provides Dimension indices: Stack ID, In Stack Position Number, Temporal Position Index 3. Data requirements: Image and Frame Type should be: Value 1: ORIGINAL, Value 2: PRIMARY, Value 3: PERFUSION Requirements for Image Display Perfusion with contrast: 1. Provide at least one viewport for display of frames with the same In-Stack Position Number (Slice-index). More viewports may be used for displaying images for other In-Stack Position Numbers= simultaneous scrolling 2. Scroll by Temporal Position Index then Stack ID / In-Stack Position Number and by Stack ID / In-Stack Position Number then Temporal Position Index 3. Provide the time since the start, deducted from Frame Reference DateTime 4. Display the values of the dimension attributes and contrast attributes 5. Display Frame annotations for Frame Number, Slice offset, relative time. CT/MR Perfusion Imaging with Contrast Process Flow

Systems Affected Systems involved in this profile are: Acquisition modalities, create the Enhanced CT or MR images PACS systems store the Enhanced images Image Displays retrieve enhanced CT/MR images and provide advanced display Actors & Transactions:

Specification Profile Status: Trial Implementation Documents: CT/MR Perfusion with Contrast Supplement (http://www.ihe.net/Technical_Framework/upload/IHE-RAD_TF_Suppl_PERF_2009-06-21.pdf) CP 221 - Update to not insist on all frames in one file - Ballot (ftp://iheyr2:[email protected]//Radiology/TF_Maintenance/4.Balloting_CPs/CP-RAD-221-PC.doc) Underlying Standards: DICOM (http://dicom.nema.org)

See Also Related Profiles

Scheduled Workflow [SWF] can manage the production of CT/MR Perfusion Images. Patient Information Reconciliation [PIR] is expected to reconcile CT/MR Perfusion Images along with the rest of the patient data record. Consistent Presentation of Images [CPI] can facilitate the Consistent Display and Print of CT/MR Perfusion Images Reporting Workflow [RWF] may use CT/MR Perfusion Images as inputs to the reporting process. Cross-enterprise Document Sharing for Imaging [XDS-I] can be used to share CT/MR Perfusion Images between sites over a network. Portable Data for Imaging [PDI] can store CT/MR Perfusion Images on media such as CDs. Import Reconciliation Workflow [IRWF] can fix patient ids, etc. of CT/MR Perfusion Images when importing. Radiation Exposure Monitoring [REM] can record radiation details associated with the creation of the CT Perfusion Images. Consumer Information Implementer Information Reference Articles This page is based on the Profile Template Retrieved from "https://wiki.ihe.net/index.php?title=CT/MR_Perfusion_Imaging&oldid=73220" Category: Profiles This page was last modified on 16 December 2013, at 09:57.