Syllabus (/syllabus/108107028/) | Lectures (/courses/108107028/) | Downloads | FAQ | Ask a question (/Clarify_doubts.php?subjectId=108107028) | Course Co-ordinated by IIT Roorkee NPTEL (/) >> Courses (/courses.php) >> Electrical Engineering (/courses.php?disciplineId=108) >> Computer Aided Power System Analysis (Web) >> Modern power system operation and control, different types of power system analysis
Question in Lecture General Introduction Modern power system operation and control, different types of power system analysis ()
Ask a Question Question Topics : Modern power system operation and control, different types of power system analysis Question: Max: 300 char
AC power flow analysis Sparse Matrices Analysis of faulted power system Security Analysis Stability Analysis
Post a new question NOTE: Before you post question check if your question already exists.Please do not repeat questions.
All Questions Question: why the voltage across the capacitor greater than applied voltage..like in fan capicitor rated at 440V but applied voltage is 230V? By: Harish Date: 2012-08-29 Answer: Although this question does not pertain to our course directly, still we would try to answer this question. The voltage rating of the fan capacitors can have some pre-specified values only and these values are given in appropriate Indian Standards. One such standard is IS : 1709 - 1984. Any capacitor manufacturer would alsways follow this standard and the capacitors are manufactured according to the specifications mentioned in this (and may be other related) standards. By: Dr. B. Das Email:
[email protected] Date: 2012-10-26 Question: what is reactive power? explain in detail please By: ANANDA KRISHNA J Date: 2012-09-02 Answer: The basic concept of this is quite clearly explianed in many basic electrical engineering textbooks. By: Dr. B. Das Email:
[email protected] Date: 2013-03-15 Question: multiples of 11, and does this factor have any influence on the hvdc converters performance if we go for other than the turns ratio which is not a multiple of 11 By: Balaji M By: balaji Date: 2012-09-07 Answer: No, not at all. The HVDC converter performance does not depend on the turns ratio of the converter transformer. Disclaimer: We will take every effort to answer your question.However, in case of delay or no response NPTEL claims no responsibility. By: Dr. B. Das Email:
[email protected] Date: 2012-10-26