Wire Recommendations - PTI Security Systems

Loading...
Wire Recommendations From PTI Security Systems We have a list of the recommended wire types for installing PTI manufactured products as well as many of the other access control and security products that we sell to compliment our system. Always refer to local code prior to ordering the wire for your site, as these requirements may be more stringent. We strongly recommend that you purchase the wire for your system from PTI as we have determined the most ideal wire over years of experience and testing. Using the incorrect wire for an application can cause many problems with voltage drop, RF Interference, and ground faults; resulting in lost revenue and greatly increased costs for service, reinstallation, repair, and technical support. Planning and installing the wiring of a site is a process that requires a high degree of technical knowledge; PTI recommends that this be done by a trained professional. If you have questions, please contact our Technical Support Department (https://support.ptisecurity.com). If you would like to purchase any of the wire recommended below that has a PTI part number, please contact our Sales Department representatives by telephone at (800) 331-6224, by email at [email protected] (mailto:[email protected]), or by using our Web Store (https://store.ptisecurity.com). Items without part numbers are not available for purchase through PTI, but are noted so that other sources may be located. PTI Power & Data Cables for Remotes (From office to keypads, muxes, relay boards, etc) Description

PTI Part #

Belden Wire Code

Resistance (In Ohms) Per 1000 Feet

18 awg, 4 conducter stranded copper wire with overall shield and common ground WWIR1804S (PVC insulation)

9418 (http://www.belden.com/techdatas/english/9418.pdf) 6.92

18 awg, 4 conducter stranded copper wire with overall shield and common ground (Plenum insulation)

89418 (http://www.belden.com/techdatas/english/89418.pdf)

6.92

18 awg, 4 conducter stranded copper wire with overall shield and common ground WWIR1804SDB 9552 (http://www.belden.com/techdatas/english/9552.pdf) 6.92 (Direct Burial) 16 awg, 4 conducter stranded copper wire with overall shield and common ground (PVC insulation)

5202FE (http://www.belden.com/techdatas/english/5202FE.pdf)

4.35

1: Standard CAT5 (shielded) cable can be used for RS485 data communications in this system. It cannot be used for power and a separate 18 gauge power wire will be needed to each device. 2: Never use any unshielded wire for data or power to AI devices. 3: Max distance for RS485 data is 4000 feet. 4: Maximum length for power varies. Refer to our page for calculating voltage drop for more information. Door Alarm Cables (From multiplexer to door switch) Description

PTI Part #

24 awg, 50 conducter solid copper wire (PVC insulation)

WWIR2450

Belden Wire Code

Resistance (In Ohms) Per 1000 Feet

9585 (http://www.belden.com/techdatas/english/9585.pdf) 25.67

24 awg, 50 conducter solid copper wire with Aluminum Mylar overall Shield (Direct Burial)

165185110 25.67 (http://www.belden.com/techdatas/english/165185110.pdf)

24 awg, 50 conducter solid copper wire (Plenum insulation)

25.67

24 awg, 24 conducter solid copper wire (PVC insulation)

9566 (http://www.belden.com/techdatas/english/9566.pdf) 25.67

1: Do not use wire smaller than 24AWG for installing door switches. 2: Do not use stranded wire for installing door switches. 3: For door alarm applications that require shielded cable, use the direct burial rated cable. Cameras and Video Description

PTI Part #

Belden Wire Code

Resistance (In Ohms) Per 1000 Feet

RG59U / 18 awg power in same cable

WWIRSiamese

549945 (http://www.belden.com/techdatas/english/549945.pdf)

10.15(Video) / 6.92(Power)

RG59U / 18 awg power in same cable (Plenum)

WWIRSiamesePL

649948 (http://www.belden.com/techdatas/english/649948.pdf)

10.15(Video) / 6.92(Power)

Coaxial Cable with 22 awg core and braided copper common ground

WWIRRG59U

8241 (http://www.belden.com/techdatas/english/8241.pdf) 10.15

Coaxial Cable with 22 awg core and braided copper common ground (Direct Burial)

8212 (http://www.belden.com/techdatas/english/8212.pdf) 10.15

Coaxial Cable with 22 awg core and braided copper common ground (Plenum)

89259 (http://www.belden.com/techdatas/english/89259.pdf)

18 awg, 2 conducter stranded copper wire with overall shield and common ground WWIR1802S (PVC insulation)

8760 (http://www.belden.com/techdatas/english/8760.pdf) 6.92

10.15

1: Maximum length for RG59 cable is 750 feet. If you have a run longer than this, you may want to consider using twisted pair wire (2450 or 2210) and Video Baluns which allow the signal to go up to 1200 feet. Two Baluns are needed per camera. This may be a more efficient solution on sites that have many cameras, or may have not installed conduit of sufficient size to accommodate co-ax cables. Intercoms Description

PTI Part #

18 awg, 10 conducter stranded copper wire with overall shield and common ground (PVC insulation)

WWIR1810S

Belden Wire Code 5345FE (http://www.belden.com/techdatas/english/5345FE.pdf)

Resistance (In Ohms) Per 1000 Feet 6.92

18 awg, 3 conducter stranded copper wire with overall shield and common ground (PVC insulation)

8770 (http://www.belden.com/techdatas/english/8770.pdf) 6.92

18 awg, 2 conducter stranded copper wire with overall shield and common ground WWIR1802S (PVC insulation)

8760 (http://www.belden.com/techdatas/english/8760.pdf) 6.92

22 awg, 10 conducter stranded copper wire with overall shield and common ground (Plenum insulation)

6508FE (http://www.belden.com/techdatas/english/6508FE.pdf)

22 awg, 4 conducter stranded copper wire with overall shield and common ground (PVC insulation)

8729 (http://www.belden.com/techdatas/english/8729.pdf) 17.5

1: Do not use wire smaller than 22AWG for installing intercoms. It is recommended that 18AWG be used for optimal results. 2: Maximum distance using 18AWG is 1600 feet. 3: Maximum distance using 22AWG is 600 feet. All of the wire gauges shown above are AWG. Below is a table that shows the cross reference to other gauge types. AWG (American Wire Gauge) SWG / Imperial (British Standard Gauge) Metric CSA (Cross Sectional Area) 16

17 or 18

14

2.50 mm2

18

18 or 19

12

2.00 mm2

20

21

8 or 9

1.50 mm2

22

22

7

1.25 mm2

24

24

6

1.00 mm2

Retrieved from "http://wiki.ptisecurity.com/index.php?title=Wire_Recommendations&oldid=662"

This page was last modified on 26 September 2014, at 11:28.

17.5

Loading...

Wire Recommendations - PTI Security Systems

Wire Recommendations From PTI Security Systems We have a list of the recommended wire types for installing PTI manufactured products as well as many o...

34KB Sizes 4 Downloads 0 Views

Recommend Documents

PTI
Ockhi: Goa assesses damage; shack owners to seek compensation · Ockhi: Centre offers all aid to Kerala; Toll put at 25 ·

Cyber Security Issues and Recommendations - International Journal
issues related to cyber security the community of security researchers- including academia, the private sector and gover

Recommendations relating to security methods - tis-gdv.de
The above-mentioned building elements should therefore be constructed in a solid design which complies as a minimum with

PTI - Health & Medicine - lovedoc.org
Oct 17, 2017 - TROMBOCITOPENIA asociado al EMBARAZO Pedro García Lázaro Hematólogo clínico HNAAA Chiclayo,10 de juli

Security Recommendations for Cloud Computing - BSI - Bund.de
Minimised risk in Cloud Computing. Cloud Computing has the long-term potential to change the way information technology

About PTI - PTI-Press Trust of India
It employs more than 400 journalists and 500 stringers to cover almost every district and small town in India. Collectiv

fullstory - PTI
1 day ago - Actor Aamir paid his respects to the actor, saying he was not just a "great star and a passionate filmmaker"

Security | FLIR Systems
FLIR professional security products offer an unmatched, integrated end-to-end security system ranging from feature rich

Home Security Alarm Systems
... County, Contra Costa County, Berkeley/Richmond, Marin County, Sonoma County, Napa County, Solano County, Stockton, M

County Security Systems - Installers of Security Systems and Burglar
Directory - County Security Systems - Security_Systems - County - BN.